User`s guide

MULTI-TASKERâ„¢
13
10. [SIG]
The Signal Present command tests for the
presence of an input signal. The card returns
either a "1" or a "0" as feedback.
1 = Signal detected
0 = No signal detected
Command Format: [SIGCnUi]
Cn = Card ID (n = # from 1 to max slots)
Ui = Unit ID (i = # from 0 to 9)
Example:
There is a properly formatted input signal being
applied to the card in slot 4. Check for the
presence of an input signal by sending the
command [SIGC4]. The feedback will be a "1"
immediately following the command sent:
[SIGC4]1
[SIGC4] = the command sent
1 = feedback, signal is present
11. [EQ]
This command is used to set the equalization
(EQ). The equalization may be set either to an
absolute number specified by the user or
incremented and decremented in steps using
the [+] and [-] commands.
ADJUST INCREMENTALLY
Command Format: [EQCnUi]
Cn = Card ID (n = slot # from 1 to max slots)
Ui = Unit ID (i = # from 0 to 9)
Example:
If there is an MT103-127/128 in slot #4, send
the command [EQC4] to make Equalization the
active command. Then use the [+] and [-]
commands to adjust. See the [+] and [-]
commands for further details.
SET AN ABSOLUTE VALUE
Command Format: [EQ=mCnUi]
m = EQ Value (m = # from 0 to 50)
Cn = Card ID (n = slot # from 1 to max slots)
Ui = Unit ID (i = # from 0 to 9)
Example:
Send the command [EQ=25C4] to set the
equalization value to 25. The [+] and [-]
commands may be used immediately following
the EQ command for further adjustment.
12. [HP]
This command is used to set the Horizontal
Position (HP). The position may be set either to
an absolute number specified by the user or
incremented and decremented in steps using
the [+] and [-] commands.
ADJUST INCREMENTALLY
Command Format: [HPCnUi]
Cn = Card ID (n = slot # from 1 to max slots)
Ui = Unit ID (i = # from 0 to 9)
Example:
If there is an MT103-127/128 in slot #4, send
the command [HPC4] to make Horizontal
Position the active command. Then use the [+]
and [-] commands to adjust. See the [+] and [-]
commands for further details.
SET AN ABSOLUTE VALUE
Command Format: [HP=mCnUi]
m = EQ Value (m = # from 0 to 20)
Cn = Card ID (n = slot # from 1 to max slots)
Ui = Unit ID (i = # from 0 to 9)
Example:
Send the command [HP=10C4] to set the
equalization value to 10. The [+] and [-]
commands may be used immediately following
the HP command for further adjustment.