User`s guide

MULTI-TASKER™
11
The Card ID is an assigned value. It is equal to
the enclosure slot number in which the card is
installed. The value can range from 1 to 4 up to
1 to 20 depending on the enclosure.
Card ID 0 (C0) is used for the controller. See
the MT100-100 User’s Guide for details.
The Group ID is a number representing a group
of cards defined with the [WR] command.
When using the Group ID, all cards in the group
will perform the given instruction.
Changing the position of a card will significantly
affect the commands recorded on software
definitions or third party control systems.
The Unit ID has a value from 0 to 9. Unit ID 0
should be used for single unit operation. If the
Unit ID is set to zero, each command may be
used without Ui. Use the command [SETU0],
as explained in the MT100-100 User’s Guide.
Example:
[VERC3]: For Unit ID Zero
[VERC3Ui]: For Unit ID other than Zero
[VERC3]: Equivalent to [VERC3U0]
1. [VER]
This command displays the software version
and card type for the MT103-127/128 card.
Command Format: [VERCnUi]
Cn = Card ID (n = slot # from 1 to max slots)
Ui = Unit ID (i = # from 0 to 9)
Example:
An MT103-128 card is in slot #4. Send the
command [VERC4], and the Multi-Tasker™
Enclosure will return the following feedback:
MT103-128 690-0197-001
MT103-128 = the card model
690-0197-001 = the software version
2. [C]
This command displays the card status.
Command Format: [CnUi]
Cn = Card ID (n = # from 1 to max slots)
Ui = Unit ID (i = # from 0 to 9)
Example:
One MT103-127/128 card is in slot #4. Send
the command [C4] and receive feedback similar
to the following:
ON,EQ=1,HP=10 C04
ON = Output is enabled (always on)
EQ = 1 = Equalization level is 1 (out of 50)
Horiz Pos = Horiz Position is 10 (out of 20)
Note: If there is no card in slot #4, sending the
[C4] command will not return any feedback.
3. [CnS]
This command saves the Equalization and
Horizontal Position settings. These values will
be restored after Reset or power up.
Command Format: [CnUiS]
Cn = Card ID (n = slot # from 1 to max slots)
Ui = Unit ID (i = # from 0 to 9)
S = Save settings
Example:
Save the settings on the card from the previous
command example. The feedback after sending
the command [C4S], for slot 4, would be:
ON,EQ=1,HP=10 C04 Saved
4. [CLR]
This command is used to clear the card and
return it to its factory settings. The default
values are Equalization equal to zero and
Horizontal Position equal to 10.
Command Format: [CLRCnUi]
Cn = Card ID (n = # from 1 to max slots)
Ui = Unit ID (i = from 0 to 9)