User`s guide
MT
MTMT
MT103
103103
103-
--
-102
102102
102
User’s Guide
400-0107-006
9
Path Operation
This command will set the path for the output, but it is not active until
the switch command, [SW], is executed. Commands ending in "P" are
not executed immediately. The path for outputs on multiple cards or
the same card may be preloaded.
Command Format: [ONmCnP]
m = Output no. (m = # from 1 to 3)
Cn = Card ID (n = slot # from 1 to max slots)
P = Path
Example:
There are two MT103-102
cards, C6 and C7. Enable Output 1 of C6
and Output 3 of C7 simultaneously by sending:
[ON1C6P]
[ON3C7P]
[SW]
15. [OFF]
This command disables outputs on a card or group of cards.
Single Card Operation
Command Format: [OFFmCn]
m = Output no. (m = # from 1 to 3)
Cn = Card ID (n = # from 1 to max slots)
Example:
An MT103-102 card is in slot 4 and all of the outputs are on.
1) [OFF1C4]: Turn off Output 1 only.
2) [OFF12C4]: Turn off Outputs 1 and 2.
3) [OFFC4]: Turn off All outputs.
Group Operation
This command disables output "m" for each card in group "k".
Command Format: [OFFmGk]
m = Output no. (m = # from 1-3)
Gk = Group ID (k = # from 1-8)
Example:
1) [OFF1G1]: Turn off Output 1 only.
2) [OFF12G1]: Turn off Outputs 1 and 2.
3) [OFFG1]: Turn off All outputs.
Path Operation
This command sets the path for the output, but it is not active until
the switch command, [SW], is sent. Commands ending in "P" are not
executed immediately. The path for multiple cards may be preloaded.
Command Format: [OFFmCnP]
m = Output no. (m = # from 1 to 3)
Cn = Card ID (n = # from 1 to max slots)
P = Path
Example:
There are two MT103-102 cards, C6 and C7. Disable Output 1 of C6
and Output 3 of C7 simultaneously using the following commands:
[OFF1C6P]
[OFF3C7P]
[SW]
16. […P]
This command will set the path for the output, but it is not active until
the switch command, [SW], is executed. Commands ending in "P" are
not executed immediately. The path for outputs on multiple cards or
the same card can be loaded. See examples in On and Off commands.
Example:
There is an MT103-102 in slot 4. Output 1 is ON and Outputs 2 and 3
are Off. The Path command has been used to set Output 1 to Off and
set Outputs 2 and 3 to On. If checking the status prior to sending the
[SW] command, the feedback will appear as follows for the above
connection settings:
ON: 1 C04 P=1,2,3
The notation "P=" at the end of the line indicates the path condition is
active. "P=1,2,3" on the status line indicates that after the [SW]
command, each output will change state. In this case, since Output 1 is
already on, it will turn off. Since Outputs 2 and 3 are off, they will
turn on.
17. [SW]
This command immediately connects inputs and outputs previously
set with the Path command. The command switches all paths set on
this card and all other cards in the enclosure.
Example:
[ON1C6P]
[OFF3C7P]
[SW]