MULTI-TASKER MANUAL PART NUMBER: 400-0226-003 MT105-110/MT105-111 8/16-IN, 8-OUT SYNC MATRIX SWITCHER CARDS FOR MULTI-TASKER USER’S GUIDE
MULTI-TASKER TABLE OF CONTENTS Page PRECAUTIONS / SAFETY WARNINGS ...............3 GENERAL ..........................................................3 INSTALLATION..................................................3 CLEANING.........................................................3 FCC / CE NOTICE..............................................3 ABOUT YOUR MT105-110/111.............................4 TECHNICAL SPECIFICATIONS............................4 DESCRIPTION OF MT105-110/111 ......................
MULTI-TASKER PRECAUTIONS / SAFETY WARNINGS • 1 Please read this manual carefully before using your MT105-110/111. Keep this manual handy for future reference. These safety instructions are to ensure the long life of your MT105-110/111 and to prevent fire and shock hazard. Please read them carefully and heed all warnings. 1.1 GENERAL • Qualified ALTINEX service personnel, or their authorized representatives must perform all service. 1.
MULTI-TASKER ABOUT YOUR MT105-110/111 2 TECHNICAL SPECIFICATIONS MT105-110/MT105-101 8/16-in 8-out Sync Matrix Switcher Cards FEATURES/ DESCRIPTION GENERAL Inputs External Input Connectors Outputs Output Connector Compatibility The MT105-110/111 16-in/8-in, 8-out Sync Matrix Switcher card is designed for use in the MultiTasker enclosure to allow the routing of computer and broadcast video in audio/visual presentation systems.
MULTI-TASKER DESCRIPTION OF MT105-110/111 4 5 5
MULTI-TASKER APPLICATION DIAGRAM 5 6 6
MULTI-TASKER Block Diagrams: Internal View of MT105-110/111 7 7
MULTI-TASKER INSTALLING YOUR MT105-110/111 Commands such as [ON], [OFF], and [IO] that end in "S" will be saved into memory. Commands not ending in "S" will still be executed but will not be restored when the system is reset (power off & power on again). 6 Step 1. Slide the MT105-110/111 into an available slot in the Multi-Tasker™ Enclosure in order to connect to the bus. Make sure that the MT105-110/111 card fits into place.
MULTI-TASKER Input8 is connected to Output5 and Output5 is disabled Example: If one MT105-110/111 card is in slot #2 of unit 3: Input7 is connected to Output6 and Output6 is disabled When sending command [VERC2U3], the MultiTasker™ Enclosure will return feedback as MT105-111 690-0126-011. Input10 is connected to Output7 and Output7 is disabled Input16 is connected to Output8 and Output8 is disabled 2. [C] This command displays the status of the card and connections of the Matrix Switcher.
MULTI-TASKER Ix = select input x (x is # from 1 to 16) [ONmGkUiS]: for a group of cards Oy = connect to output y (y is # from 1 to 8) This command enables output "m" for each card in group "k" of unit "i". Cn = card ID number (n is # from 1 to 19) (1 to 8 for MT100-101 or 1 to 4 for MT100-106) m = card output (m = # from 1-8) Ui = unit ID, i is # from 0 to 9). (Refer to MT100100 user’s guide to set Unit ID).
MULTI-TASKER m = card output (m = # from 1-8) [ON…..F]: feedback After processing a command, an OK or ER will be returned as feedback if "F" is included at the end of a command string or if the unit ID is zero. k = group number (k = # from 1-9) (1 to 8 for MT100-101 or 1 to 4 for MT100-106) Example: S = saves command to memory i = unit number (i = # from 0-9) [ON1C2U3F]: if path is not set Example: [ON1C2U3PF]: if path is set 1. [OFF1G5U1]: Turns OFF output 1 for each card in group5 of unit 1. 5.
MULTI-TASKER Example: [CLRCnUi]: for a single card n = Card ID number (n = 1 to 19) (1 to 8 for MT100-101 or 1 to 4 for MT100-106) [OFF1C2U3F]: if path is not set [OFF1C2U3PF]: if path is set Ui = Unit ID number (i = 0 to 9) 6. [SW] – Switch Note that all outputs will be connected to input1. The switch command immediately connects inputs and outputs, which were previously set with the path command on this card or any other cards in the MT100-100.
MULTI-TASKER 10. [RD] TROUBLESHOOTING GUIDE This command displays the members in each group. 8 We have carefully tested and have found no problems in the supplied MT105-110/(111); however, we would like to offer suggestions for the following: Command Format: [RDGkUi] k = group number (k = # from 1-9) NO DISPLAY Cause 1: The source has a problem.
MULTI-TASKER ALTINEX POLICY 9 9.0 LIMITED WARRANTY / RETURN POLICY Please see the Altinex website at www.altinex.com for details on warranty and return policy. 9.1 CONTACT INFORMATION ALTINEX, INC. 592 Apollo Street Brea, CA 92821 USA TEL: 714-990-2300 TOLL FREE: 1-800-ALTINEX WEB: www.altinex.com E-MAIL: solutions@altinex.