User`s guide
MULTI-TASKERâ„¢
11
Example:
Send the command [?C10] to receive the
feedback for the MT103-122 in slot #10. Each
status field begins with a '+' and ends with the
card slot number (ex: C10). The feedback will be
similar to the following:
[+MT103-122C10+VR690-0197-001C10
+ON123456C10+EQ0C10+SI0C10]
MT103-122..........Card Type
VR690-0197-001.Firmware version
ON.......................Outputs are ON
EQ0 .....................Equalization is set to zero
SI0.......................Signal (SI), 0= no signal
5. [SIG]
This command will test for the presence of an
input signal and return a '1' if a signal is present
and return a '0' if no signal is present.
Command Format: [SIGCnUi]
Cn = Card ID (n = # from 1 to max slots)
Ui = Unit ID (i = from 0 to 9)
Example:
If there is an MT103-122 in slot #10 and there is a
valid CAT5 signal present on the input, sending
the command [SIGC10] will yield the following
feedback:
1
6. [STA]
This command enables or disables automatic
feedback from the front panel. The command
affects any card with auto-feedback capability,
not just the MT103-122. The default at power on
or reset is STA0, OFF.
Command Format [STA1] = ON
Command Format [STA0] = OFF
Feedback Prefix Definitions:
+MT = Card Number
+VR = Firmware Version
+ON = On/Off Control
+EQ = Equalization
+SI = Signal Detect
Example:
Command = [EQ=25C10]
Feedback = +EQ25C10
+EQ = Equalization
25 = Equalization Level
C10 = Card slot number
7. [CLR]
This command clears the card settings and
returns it to the factory default values.
Command Format: [CLRCnUi]
Cn = Card ID (n = slot # from 1 to max slots)
Ui = Unit ID (i = # from 0 to 9)
Example:
In order to clear the card in slot #10, send the
command [CLRC10].
8. [EQ] and [+] / [-]
This command is used to display the current
Equalization setting, set the video equalization or
to select the Equalization function for adjustment
using the [+] and [-] commands.
DISPLAY THE EQUALIZATION SETTING
Command Format: [EQCnUi]
Cn = Card ID (n = slot # from 1 to max slots)
Ui = Unit ID (i = # from 0 to 9)
Example:
An MT103-122 card is in slot #10 and the
equalization level is set to zero. Send the
command [EQC10] and receive the following
feedback:
EQ=0