Hardware Owner's manual

AltiGen Triton/Proton Telephony Boards
Telephony Hardware Manual 41
Do not have any board terminated in the middle of MVIP bus. It will cause a clocking
error and unpredictable voice quality.
Always run the CT-Bus Test Tool when you add a new board to the system.
For complete instructions on how to install
telephony boards, please refer to the Quick
Installation Guide, which is provided with every AltiGen telephony board package.
Limitations
The next table shows the maximum number of each type of board that can be installed
in one system.
Table 2. Maximum Boards in One System
Board Type
Max. in a
System
Total Ports
Triton VoIP configured as 12-
port
10 120
Triton VoIP configured as 30-
port
4
a
120
TOTAL Triton VoIP boards 10
120 max in one system, via any
combinati
on of boards that complies with
the system limitations shown here
Triton Conf 30-Party 1
10 conference bridges, 30 conference
me
mbers
Triton Analog Trunk 16 192
Proton Analog Trunk 16 128
Triton Analog Extension 16 192
Triton T1/E1/PRI 8 192 (T1), 240 (E1)
Triton Resource 2 24 sessions
a. Requires 3GHz CPU w/Hyperthreading
Power Requirements
(Requisitos de Energía Eléctrica/Energiebedarf)
The power requirements are as follows for each individual board:
Los requisitos de energía eléctrica son los que se indican a continuación para cada tarjeta
individual/Di
e folgende Tabelle zeigt den Energiebedarf jeder einzelnen Karte an: