Owner manual

Chapter 30: Tools and Applications
376 MaxCS 7.5 Administration Manual
CT-Bus Test Tool
The CT-Bus Test Tool is a tool that detects one-way connection, cross talk, bad MVIP cable and static noise
problems.
To run the CT-Bus test tool,
1. Stop AltiGen Switching Services before running this utility.
2. Launch CT-Bus Test Tool from Start > All Programs > MAXCS > Gateway Tools > CT-Bus Test Tool.
3. Click Start to begin the test.
4. At the end of the test, the utility provides pass or fail results.
Backup and Restore Utility
Note: The configuration backup option is turned on by default.
Backups do not include CDRs.
To back up or restore data, select either
From MaxAdmin: Services > Utilities > Backup and Restore, or
From the Windows Start menu: All Programs > MAXCS > Utilities > MAXCS ACC/ACM Backup and
Restore.
Figure 221. Backup and Restore window
Note: The Backup and Restore window can only be accessed at the primary MAXCS system; it is not
available from a remote MaxAdmin client.
Backing Up Files
Note: The AltiGen backup utility does not back up internal CDR database. You must back up the internal
CDR database from \AltiDB\InternalDB\Internal.mdb manually.