Owner manual

Chapter 27: System Report Management
346 MaxCS 7.5 Administration Manual
Configure traps:
Memory usage exceeds – This trap is sent when MAXCS detects that the lowest virtual memory usage
exceeds a specified percentage of physical memory configuration within a 10-minute duration. Default val-
ue is 80%. The next trap will be sent after the condition is cleared then occurs again. The minimum dura-
tion between any two consecutive traps is 30 minutes
Average CPU utilization exceeds – This trap is sent when MAXCS detects its average CPU utilization
exceeds a specified percentage in any 10-minute duration. Default value is 80%. The next trap will be sent
after the condition is cleared then occurs again. The minimum duration between any two consecutive traps
is 30 minutes
Hard disk usage exceeds – This trap is sent when hard disk usage of MAXCS transitioning from below
threshold to on or above threshold is detected. Default value is 80%. The minimum duration between any
two consecutive traps is 30 minutes.
List of Traps Sent
A trap is sent when the following conditions are detected.
Cold Start (generic trap). When AltiServ is cold started and initialized successfully.
Warm Start (generic trap). When AltiKeep service detects AltiServ.exe is down, re-starting AltiServ.exe,
and AltiServ is initialized successfully.
LinkDown (generic trap). When detecting a T1/E1/PRI span state is transitioning from up to down or losing
clock source.
When a gateway is down, one trap is sent for each T1/E1/PRI interface in this Gateway. This trap is sent
when SIP trunk destination state transitioning from reachable to unreachable is detected.
Every T1/E1/PRI span and SIP trunk channel is assigned a unique "ifIndex" value as a port identifier
LinkUp (generic trap). When a T1/E1/PRI span state transitioning from down to up is detected.