User guide
Setting General Trunk Attributes
AltiWare OE System Administration Manual 73
Trunk Configuration
• Attribute—In Service makes the trunk available for use. Out of
Service prevents the trunk from being used (for example, while
performing maintenance).
• Tenant Selection—the Tenant group assignment for the trunk,
configured from the Tenant Table window in System Configuration,
discussed on page 46. If no tenant is selected, any extension can use
this trunk to make an out call.
• Enable Tie Trunk—to allow hop-on and hop-off dialing for a ISDN/
PRI, or T1 trunk. When this box is checked, any incoming call to the
selected trunk can be sent with ANI/DNIS information. To use this
feature, Hop-off must also be enabled under System Configuration
Call Restrictions, as discussed on page 33. Also, the board must be
configured to allow for Tie Trunks. See “Setting up T1 or PRI
Channels on the Triton T1/PRI Board” on page 65.
• Trunk Properties button—opens a dialog box that allows you to
configure low-level, hardware-specific properties for each trunk. The
options vary depending on the type of board and trunk, and this is the
topic of subsequent sections in this chapter.