Specifications

Troubleshooting
44 IP 705 Manual
IP phone registered then
goes back to Basic mode
Check network connectivity by pinging from
AltiServ to the IP phone.
Check if IP Phone Service is running.
Check if there is a duplicate IP address by
unplugging the Ethernet cable on the IP phone, then
pinging the IP 705 phone’s IP address.
Check the extension’s IP address in AltiAdmin to
find out if another user is trying to log in using the
same extension number.
Use #27 then Enter to log in again and see if the
problem persists.
No IP Address
Check if DHCP is enabled. If YES, check network
connection. If NO, verify that your DHCP server is
correctly configured.
Check if IP 705 phone’s IP address is configured.
One way connection
Make sure firewall setting has all the TCP/UDP
ports required by AltiWare opened.
If NAT is used, make sure NAT is enabled and NAT
address is set up correctly.
Phone does not show
anything on LCD display
Check the power source to be sure the IP 705 phone
is receiving power.
Poor voice quality
Make sure a Layer 3 Managed Ethernet switch is
used, rather than a hub or non-managed switch, in
the corporate LAN.
G.711 provides better voice quality.
If VoIP is set up over WAN, set priority queuing on
the WAN router.
Make sure WAN QoS is okay by pinging a few
hundred packets from remote site and observe
packet loss and network latency.
Adjust jitter buffer to accommodate network
latency.