Specifications
MaxSupervisor Manual 15
Getting Started
Error Messages
The following errors may be displayed as login or connectivity errors.
Error Message Description Solution
MAXCS connection limit
has been exceeded.
No MaxSupervisor was
found OR more than
allowed number of Max-
Supervisor users have
attempted to log on.
Administrator must maintain the
number of MaxSupervisor license
keys or add additional seat licens-
ing.
Cannot connect to AltiLink.
Please check server name
or network connection.
You are not connected to
MAXCS.
Check the server field (IP address
or DNS name) by:
1. Pinging the network server
address OR
2. Try using the IP address of
MAXCS (if using the DNS name
in the server field).
Please register AlpInter-
face.dll (regsver32
AlpInterface.dll).
MaxSupervisor uses this
dll to communicate with
MAXCS. It should be reg-
istered in the user’s sys-
tem.
Re-register this file. Type in DOS
command window, regsver32
AlpInterface.dll
Change directory to MaxSupervi-
sor directory, type regsver32
AlpInterface.dll
You have entered an invalid
password. Please try again.
The password is incorrect. Enter your extension password.
The version of MaxSuper-
visor on your desktop is out
of date.
The installed version of
MaxSupervisor does not
match the version of
MAXCS on the system
server.
Upgrade MaxSupervisor to match
the current running version of
MAXCS.