Specifications

ACM Redundancy
AltiContact Manager Administration Manual 23-3
23. AltiWare
Redundancy
11. Connect an analog extension of the primary system to A bridge of K-
AB K16-T50-L-R card.
12. Connect an analog extension of the secondary system to B bridge of K-
AB K16-T50-L-R card.
13. Connect a patch panel to A bridge of K-AB switch with a standard 25-
pair telco cable for analog extensions and analog trunks.
Configuration Procedures
At the Primary Server:
1. Configure primary system boards, reboot if necessary.
2. Set configurations to the primary system, such as extensions, trunks,
VoIP dialing tables, etc.
3. Go to the Redundancy Configuration window (select Redundancy
from the System Management menu), and:
Check the Enable Redundancy check box.
Enter IP address for the Primary Address, Secondary Address,
and AB-Switch Address.
— Enter a Redundancy Key (your password for redundancy; needs to
be the same for Primary and Secondary systems).
Figure 2. Redundancy Configuration - Primary System
Click OK or Apply when finished.