Triton Analog Trunk GS/LS Properties
7-18 AltiContact Manager Administration Manual
3. Set the Timeout to Repeat Current Level.
Figure 8. Setting Timeout to Repeat Current Level
4. Set trunk In Call Routing of the tested trunks to this IVR.
Figure 9. Setting trunk In Call Routing to an IVR
5. Call from one trunk to another one. You should hear a 1K Hz tone
playing at the originating side.
6. While the tone is playing, measure the Rx Level at the trunk that is
making the outgoing call.
If the reading is less than -6 dB, for example -3 dB, take the
following steps to attenuate the gain for the Triton Analog Trunk to
IP phone connection: