Specifications
Trunk Configuration
AltiContact Manager Administration Manual 7-15
7. Trunk
Configuration
The Match Result Button
Clicking the Match Result button shows you the result you got the last
time you clicked the Match Impedance button for that trunk. The
following dialog box is displayed:
Figure 6. Impedance Match Result dialog box
Measuring the Rx Level of a Trunk Channel
In order to perform this test, you need to obtain the local CO’s Milli-Watt
Test Number from your CO. When dialing this number, a 0dB tone is sent.
For example, if your number is 510-252-9712, the Milli-Watt Test Number
from the local CO is 510-252-0020 (the prefix 510-252 is the same).
1. Write down the Rx Gain, then set it to 0dB and click OK.
2. Write down the Impedance setting, then change it to 600ohm, and
click OK.
3. Call the number you got from your CO, as noted above.