Triton Analog Trunk GS/LS Properties
7-12 AltiContact Manager Administration Manual
Enable Answer
Debounce (Incoming)
Enables a timeout period of 2 seconds (for ignoring
false CO disconnect signal), after answering an
incoming call.
Loop Break Duration
(ms)
Disconnects signal if CO breaks loop current. You
can set the duration from 200 to 1000 ms.
Tone Disconnect Busy tone (reorder tone, fast busy tone, error tone,
etc.) or dial tone (continuous tone, etc.). This should
be used in conjunction with drop in loop current. For
COs who cannot guarantee loop break, this may be
the only option.
Receiver/
Transmission Gain
Slide setting adjusts the incoming volume from -6 dB
to 6 dB for every Triton Analog Trunk channel.
The default setting is 0 dB, and it is highly
recommended that you not change this setting.
Caution: Setting the volume too high will cause
distortion in voice quality and/or
missed DTMF digits.
Trunk to Trunk Gain The gain in the Triton analog trunk to Triton analog
trunk connection, in dB.
Last Diagnosis Time The last time the Diagnosis button was clicked.
Diagnose button Use this button view the Noise Level, Echo Return
Loss, and Hybrid Echo Return Loss, measured using
the current Impedance setting. Acceptable range for
Noise Level is less than -67dBm in value. Acceptable
range for Echo Return Loss is less than -12dB. For
example, Noise Level of -72 dB is good and -63 dB
is poor; Echo Return Loss of -19 dB is good and -8dB
is poor.
Noise Level The noise level (displayed after you click the
Diagnose button or the Match Impedance button).
Echo Return Loss The measurement for echo return loss (displayed
after you click the Diagnose button or the Match
Impedance button).
Hybrid Echo Return
Loss
The measurement for hybrid echo return loss
(displayed after you click the Diagnose button or the
Match Impedance button).