Specifications
Table Of Contents
- Preface: About This Manual
- Overview
- Key AltiContact Manager Characteristics
- Call Center/IP PBX Features
- Automatic Call Distribution Features
- IVR Features
- AltiGen Voice Mail Features
- Internet Integration Features
- System Administration Features
- T1/PRI/E1 Features
- Voice over IP Features
- Voice over IP Session Support AltiContact Manager Features
- AltiWare Tools
- Optional Add-On Software
- Optional Add-On Products
- Optional Kits
- Key AltiContact Manager Characteristics
- System Requirements
- Hardware Requirements
- System Key Requirement
- Selecting the AltiContact Manager Platform
- Minimum System Requirements
- Proper Grounding and Loop Current
- Uninterruptible Power Supply (UPS)
- Operating Environment
- AltiGen Telephony Boards
- Functional Specifications
- AltiGen Board Installation
- AltiGen Board Options
- System Limitations
- Power Requirements
- Heat Factor
- Installing a Cooling Fan
- Proper Board Handling Procedures
- Electrostatic Discharge (ESD) Warning
- Operating Environment
- Packaging for Shipment and Storage
- AltiContact Manager Conference Resource Limits
- Software Installation
- Software License Activation and Registration
- New Installation
- Upgrading AltiWare OE
- License Activation and Registration Process
- Online License Registration Procedures
- Manual Online License Registration Procedure
- Offline Registration Procedures
- Windows Emergency Repair Disk
- Installing ACM Administrator on Remote Systems
- Running ACM Administrator
- Shutting Down AltiContact Manager when Changing or Adding Hardware
- Transferring the AltiContact Manager to Another Server Chassis
- AltiContact Manager Uninstall
- Software Installation Troubleshooting
- Getting Around ACM Administrator
- System Configuration
- Setting General Parameters
- Setting a System Number Plan
- Setting Business Hours
- Routing Calls on Holidays
- Configuring System Speed Dialing
- Defining System Call Restrictions
- Creating Account Codes
- Setting up Call Reports
- Using a Tenant Table
- Country Relevant
- CT-Bus Clock Configuration
- Audio Peripheral Configuration
- Board Configuration
- Trunk Configuration
- Voice Mail Configuration
- VoIP Configuration
- Defining an IP Dialing Table
- Setting VoIP Codecs
- Network Configuration Guidelines for VoIP
- Network Configuration Guidelines for the Alti-IP 600
- Configuration Guidelines for NAT
- Firewall Considerations
- Setting up H.323 Traffic Forwarding for H.323 NAT
- Setting Up an AltiContact Manager-to- AltiContact Manager IP Network
- Out Call Routing Configuration
- IVR Configuration
- CallCenter Configuration
- Agent Configuration
- Huntgroup Configuration
- Workgroup Configuration
- Setting Up IP Extensions
- Alti-IP 600 Phone Configuration
- Application Extension Configuration
- System Data Management
- System Report Management
- Data and Internet Integration
- AltiWeb
- Using TAPI
- Tools
- Basic Call Router & Call Router Advanced
- Call Accounting Report Formats
- E1 R2 CAS Installation
- Product Repair Services & Technical Support
- Glossary
- Index
- Readers Comment Form
xvi AltiContact Manager Administration Manual
a. The telephone number to which this unit is connected.
b. The ringer equivalence number. [0.0B]
c. The USOC jack required. [RJ11C]
d. The FCC Registration Number. [see label on board]
e. Industry Canada (Industrie Canada) Certification Number.
[see label on board]
Items (b) and (d) are indicated on the label. The Ringer Equivalence Number (REN) is used
to determine how many devices can be connected to your telephone line. In most areas, the
sum of the RENs of all devices on any one line should not exceed five (5.0). If too many
devices are attached, they may not ring properly.
Service Requirements
In the event of equipment malfunction, all repairs should be performed by our Company or an
authorized agent. It is the responsibility of users requiring service to report the need for service
to AltiGen or to one of our authorized agents. Service can be obtained at your Authorized
AltiGen Dealer.
Equipment Attachment Limitations - Industry Canada
NOTICE: The Canadian Industry Canada label identifies certified equipment. This
certification means that the equipment meets certain telecommunications network protective,
operational, and safety requirements. The Department does not guarantee the equipment will
operate to the user’s satisfaction.
Before installing this equipment, users should ensure that it is permissible to be connected to
the facilities of the local telecommunications company. The equipment must also be installed
using an acceptable method of connection. In some cases, the company’s inside wiring
associated with the single line individual service may be extended by means of a certified
connector assembly (telephone extension cord). The customer should be aware that
compliance with the above conditions may not prevent degradation of service in some
situations.
Repairs to the certified equipment should be made by an authorized Canadian maintenance
facility designated by the supplier. Any repairs or alterations made by the user to this
equipment, or equipment malfunctions, may give the telecommunications company cause to
request the user to disconnect the equipment.
Users should ensure for their own protection that the electrical ground connections of the
power utility, telephone lines, and internal metallic water pipe system, if present, are
connected together. This precaution may be particularly important in rural areas.
Caution: Users should not attempt to make such connections themselves, but should
contact the appropriate electrical inspection authority, or electrician, as
appropriate.
The Load Number (LN) assigned to each terminal device denotes the percentage of the total
load to be connected to a telephone loop that is used by the device, to prevent overloading.
The termination on a loop may consist of any combination of devices subject only to the
requirement that the total of the Load Number of all the devices does not exceed 100.
WARNING: Changes or modifications to this unit not expressly approved in writing
by AltiGen Communications, Inc. could void the user’s authority to
operate this equipment.