User guide
Table Of Contents
- About This Manual
- Overview
- Technology Enhancements in Release 5.1
- SIP Implementation
- Multi-Site Enterprise Management - AltiEnterprise Manager
- Multi-Chassis Gateway Support (ACM only)
- Capacity Improvements
- Voice Processing New Features and Enhancements
- PBX New Features and Enhancements
- Call Center New Features and Enhancements
- Client Application New Features and Enhancements
- IP Phone New Features and Enhancements (IP600, IP710, IP705)
- Key System Features
- Technology Enhancements in Release 5.1
- Software Installation & License Registration
- Getting Around AltiWare Administrator 5.1
- System Configuration
- Setting General Parameters
- Setting a System Number Plan
- Setting Business Hours
- Routing Calls on Holidays
- Configuring System Speed Dialing
- Defining System Call Restrictions
- Creating Account Codes
- Setting up Call Reports
- Country-Relevant Settings
- Audio Peripheral Configuration
- Activity
- Feature Profiles
- CT-Bus Configurations
- Voice Mail Configuration
- Auto Attendant Configuration
- Board Configuration
- Using the Triton Resource Board
- Using the Triton MeetMe Conference Board
- Configuring the Quantum Board
- Configuring the Triton Analog Station Board
- Configuring the Triton Analog Trunk LS/GS and LS Boards
- Configuring the Triton VoIP Board
- Configuring the Triton T1/E1 Board
- Configuring Virtual Boards SIPSP and H323SP
- Configuring the MAX Board
- Configuring the Virtual MobileExt Board
- Trunk Configuration
- Trunks Out of Service
- Channel Identification
- Opening the Trunk Configuration Window
- Selecting Trunks to Set Attributes
- Configuring One or Multiple Trunks
- Setting General Trunk Attributes
- H323 Tie Trunk Properties
- SIP Tie Trunk Properties
- SIP Trunk Properties
- Triton T1/E1 Trunk Properties
- Triton Analog Trunk GS/LS Properties
- Quantum Trunk Properties
- Incoming Call Routing
- Outgoing Call Blocking
- In Call Routing Configuration
- Out Call Routing Configuration
- Extension Configuration
- Setting Up IP Extensions
- AltiGen IP Phone Configuration
- Mobile Extension Configuration
- Hunt Group Configuration
- Paging Group Configuration
- Line Park Configuration
- Workgroup Configuration
- Managing and Using MeetMe Conference
- Network Configuration Guidelines for VoIP
- Enterprise VoIP Network Management
- Understanding VoIP Bandwidth Requirements
- Opening AltiEnterprise Manager
- Setting VoIP Codec Profiles
- Assigning Codec Profiles to IP Addresses
- Defining IP Networks
- Defining the IP Dialing Table
- The Multi-site VoIP Domain
- Working with Servers in the VoIP Domain
- Managing VoIP Domain Users
- Configuring Global Least Cost Routing
- When Information May Be Out of Sync
- System Report Management
- Tools and Applications
- E1-R2 and E1 ISDN PRI Installations
- Required Service Parameters
- Network Ports
- Technical Support & Product Repair Services
- Troubleshooting
- Index

102 AltiWare ACC 5.1 Administration Manual
Setting General Trunk Attributes
Select a channel to view its current attributes. You can then set or change the following
attributes. If an option is grayed out, it is not available for that type of trunk:
• Access Code—Assign a trunk access code to the selected trunk. If you need to use
a trunk access code other than 9, you must first set this up on the Number Plan
tab of System Configuration (see “Setting a System Number Plan” on page 50).
Note: There are two types of access code: Trunk Access Code (TAC) and Route
Access Code (RAC). TAC is a quick and easy way to select which trunk(s) you
would like to dial out from, especially when you want to reserve trunks for a
special dialing purpose. For example, you can set up TAC "7" and assign that
to trunk(s). These trunks will be reserved exclusively for users who know the
TAC "7".
Although TAC is easy to use, it does have limitations especially when you are
located in an area with a complicated dialing pattern or you need to set up
VoIP hop-off dialing.
RAC uses the Out Call Routing table, which has the flexibility to group trunks
into a route, assign routes to a specific dialing pattern, and add/delete digits
from the dialing pattern. It can solve most of the complicated dialing
problems. If your system is using RAC, you can set this TAC field to "None".
• Area Code—The local area code for each trunk. Enter a three-digit area code. If left
blank, the trunk assumes the home area code defined in the General tab of the
System Configuration window. This configuration is for each trunk in the system and
will negatively affect features such as Zoomerang if the area code is not configured
properly.
• Direction—The trunk direction can be Outgoing only, Incoming only, Both
Outgoing and Incoming, Paging, or E911. The Both option is the system default.
Important: If a trunk is in the hunt group of your company main number and you
configure this trunk as an "Outgoing" trunk, the incoming call will be
rejected by the system. To avoid this mistake, make sure you check
with your carrier to verify the hunting number before you configure a
trunk to Outgoing.