User guide

Chapter 25: Enterprise VoIP Network Management
MAXCS ACC 6.7.1 Administration Manual 331
1. Click the Global LCR Button.
2. On the Global LCR screen, click Add.
3. Fill in the dialog box and click OK.
Parameter Description
Enable Check this check box to enable the configuration.
E.164 Number
Pattern
E.164 is the ITU standard format for international telephone num-
bers. Enter a country code and area code. For example, the num-
ber pattern for a site in Fremont, Calif., would be 1510 (the coun-
try code 1, followed by the Fremont area code 510).
Calling From
Select the server from which the call originates, or select All
Servers.
Transit Through Select the server that receives the call.
4. After adding a route, click Edit, check the Enable check box, and click OK to
activate the Global LCR route.
To edit an entry made to the Global Least Cost Routing table, select the entry you want
to change, and click the Edit button. Make your changes, and click OK.