User guide

Chapter 25: Enterprise VoIP Network Management
MAXCS ACC 6.7.1 Administration Manual 309
To define an address range
1. Click the Add button in the IP Network panel.
2. Fill in a range of IP addresses.
3. Select the pipe for this IP address range.
4. If this is a private network, check the Private Network check box. Click OK.
To edit a network you’ve added, select it and click the Edit button. To remove it, select
it and click the Remove button.
Configuring a Public or Intranet Pipe
If you want to regulate how many VoIP sessions can be connected to the server through
a Public or Intranet Pipe,
1. In the Public Pipe panel, check the Enable box.
2. Enter the maximum WAN bandwidth you want to allocate to VoIP connections. The
system will calculate the maximum sessions for each type of codec automatically.
3. You can change the G.711 sessions by using the Up/Down arrow button.
Notes
When calculating the maximum sessions for each codec, the system uses the follow-
ing bandwidth requirement to ensure that each session has some safety margin:
G.711 - 90 kbps
G.729 - 30 kbps
G.723 - 24 kbps
It is recommended that you use 20ms frame size for G.711 and G.729 when config-
uring a Codec Profile.