Chapter 11: Board Configuration
MAXCS ACC 6.7.1 Administration Manual 121
Setting up Channels on the Triton T1/E1 Board
This section discusses setting up T1 CAS, T1 PRI, E1 CAS, or E1 PRI channels on the
Triton T1/E1 board.
Click the Protocol button in the T1 or E1 configuration dialog box (see Figure 64) to
open the Protocol Configuration window, shown below. The Triton T1/E1 Board can
be configured to either CAS or PRI through the configuration options in the window.
The CH -> Type list on the left side of the window displays the channel types.
Note: In a tie-trunk configuration, set the trunks to “Out of Service” before changing the
trunk type from T1 to PRI or vice versa. Otherwise, the system will generate gar-
bage call records to your internal or external logger service. See “Setting General
Trunk Attributes” on page 141 for details.
Figure 65. T1 PRI Protocol Configuration dialog box (top half)