User guide
Table 4-7: User-coded Reset Controller, Transceiver PHY, and TX PLL Signals
Signal Name Direction Description
pll_powerdown
Output Resets the TX PLL when asserted high.
tx_analogreset
Output Resets the TX PMA when asserted high.
tx_digitalreset
Output Resets the TX PCS when asserted high.
rx_analogreset
Output Resets the RX PMA when asserted high.
rx_digitalreset
Output Resets the RX PCS when asserted high.
clock
Input Clock signal for the user-coded reset controller. You can use the
system clock without synchronizing it to the PHY parallel clock.
The upper limit on the input clock frequency is the frequency
achieved in timing closure.
pll_cal_busy
Input A high on this signal indicates the PLL is being calibrated.
pll_locked
Input A high on this signal indicates that the TX PLL is locked to the ref
clock.
tx_cal_busy
Input A high on this signal indicates that TX calibration is active. If you
have multiple PLLs, you can OR their pll_cal_busy signals
together.
rx_is_lockedtodata
Input A high on this signal indicates that the RX CDR is in the lock-to-
data (LTD) mode.
rx_cal_busy
Input A high on this signal indicates that RX calibration is active.
rx_is_lockedtoref
Input A high on this signal indicates that the RX CDR is in the lock-to-
reference (LTR) mode. This signal may toggle or be deasserted
when the CDR is in LTD mode.
Combining Status or PLL Lock Signals
You can combine multiple PHY status signals before feeding into the reset controller as shown below.
UG-01143
2015.05.11
Combining Status or PLL Lock Signals
4-19
Resetting Transceiver Channels
Altera Corporation
Send Feedback