Parameter Value
Enable rx_seriallpbken port On / Off
Table 2-70: RX PMA Parameters
Parameter Value
Number of CDR reference clocks 1 to 5
Selected CDR reference clock 0 to 4
Selected CDR reference clock
frequency
Select legal range defined by the Quartus II software
PPM detector threshold 100, 300, 500, 1000
CTLE adaptation mode manual, triggered
DFE adaptation mode continuous, manual, disabled
Number of fixed dfe taps 3, 7
Enable rx_pma_clkout port On / Off
Enable rx_pma_div_clkout port On / Off
rx_pma_div_clkout division factor When Enable rx_pma_div_clkout port is On, then:
Disabled, 1, 2, 33, 40, 66
Enable rx_pma_clkslip port On / Off
Enable rx_pma_qpipulldn port (QPI) Off
Enable rx_is_lockedtodata port On / Off
Enable rx_is_lockedtoref port On / Off
Enable rx_set_locktodata and rx_set_
locktoref ports
On / Off
Enable rx_seriallpbken port On / Off
Enable PRBS verifier control and
status ports
On / Off
2-92
Native PHY IP Parameter Settings for Interlaken
UG-01143
2015.05.11
Altera Corporation
Implementing Protocols in Arria 10 Transceivers
Send Feedback