13. In the Completing the Add/Remove Hardware Wizard window,
click Finish. A system dialog appears prompting a reboot so that the
new settings can take effect.
Confirming the
Installation
After the system is rebooted, follow the steps below to ensure the
ByteBlaster driver is accessible:
1. Connect the ByteBlasterMV cable to the PC’s parallel port LPT1.
2. Open a command prompt window.
3. Type jtagconfigr at the command prompt.
4. If the PC cannot connect to the ByteBlasterMV cable, the following
message appears:
Unable to lock chain (Hardware not attached)
5. Type jtagconfig --add ByteBlaster LPT1r.
You can now use the ByteBlasterMV cable to configure the EPXA1
development board.