Specifications

The POR circuitry checks the functionality of the I/O level shifters powered by the V
CCPD
and V
CCPGM
power supplies during power-up mode. The main POR circuitry waits for all the individual POR circuitries
to release the POR signal before allowing the control block to start programming the device.
Figure 10-5: Simplified POR Diagram for Cyclone V Devices
V
CC
PORV
CC
V
CC_AUX
POR
Modular
Main POR
Main POR
V
CC_AUX
V
CCPD
V
CCPGM
Related Information
Cyclone V Device Datasheet
Provides more information about the POR delay specification and t
RAMP
.
Power Supplies Monitored and Not Monitored by the POR Circuitry
Table 10-2: Power Supplies Monitored and Not Monitored by the Cyclone V POR Circuitry
Power Supplies Not MonitoredPower Supplies Monitored
V
CCE_GXBL
V
CCH_GXBL
V
CCL_GXBL
V
CCA_FPLL
V
CCIO
V
CCIO_HPS
V
CCPLL_HPS
V
CC_AUX
V
CCBAT
V
CC
V
CCPD
V
CCPGM
V
CC_HPS
V
CCPD_HPS
V
CCRSTCLK_HPS
For the device to exit POR, you must power the V
CCBAT
power supply even if you do not use the
volatile key.
Note:
Related Information
Reset Manager
Provides information from the Hard Processor System Technical Reference Manual.
Configuration, Design Security, and Remote System Upgrades in Cyclone V Devices
Provides more information about the MSEL pin settings for each POR delay.
Power Management in Cyclone V Devices
Altera Corporation
Send Feedback
CV-52010
Power Supplies Monitored and Not Monitored by the POR Circuitry
10-6
2013.06.28