Table 7-2: MSEL Pin Settings for Each Configuration Scheme of Cyclone V Devices
Valid MSEL[4..0]Power-On Reset
(POR) Delay
V
CCPGM
(V)Design Security
Feature
Compression
Feature
Configuration Scheme
10100Fast
1.8/2.5/3.0/3.3DisabledDisabled
FPP x8
11000Standard
10101Fast
1.8/2.5/3.0/3.3EnabledDisabled
11001Standard
10110Fast
1.8/2.5/3.0/3.3
Enabled/
Disabled
Enabled
11010Standard
00000Fast
1.8/2.5/3.0/3.3DisabledDisabled
FPP x16
00100Standard
00001Fast
1.8/2.5/3.0/3.3EnabledDisabled
00101Standard
00010Fast
1.8/2.5/3.0/3.3
Enabled/
Disabled
Enabled
00110Standard
10000Fast
1.8/2.5/3.0/3.3
Enabled/
Disabled
Enabled/
Disabled
PS
10001Standard
10010Fast
3.0/3.3
Enabled/
Disabled
Enabled/
Disabled
AS (x1 and x4)
10011Standard
Use any valid MSEL pin
settings above
——DisabledDisabledJTAG-based
configuration
You must also select the configuration scheme in the Configuration page of the Device and Pin
Options dialog box in the Quartus II software. Based on your selection, the option bit in the
programming file is set accordingly.
Note:
Related Information
Cyclone V Device Family Pin Connection Guidelines
Provides more information about JTAG pins voltage-level connection.
Configuration Sequence
Describes the configuration sequence and each configuration stage.
Altera Corporation
Configuration, Design Security, and Remote System Upgrades in Cyclone V Devices
Send Feedback
7-3
Configuration Sequence
CV-52007
2013.06.11