User manual

Configuring the EPCS64 in
AS Mode (2/2)
1. Ensure that power is applied to the DE2-115 board.
2. Connect the supplied USB cable to the USB Blaster port on the
DE2-115 board.
3. Configure the JTAG programming circuit by setting the
RUN/PROG slide switch (SW19) to the PROG position.
4. The EPCS64 chip can now be programmed by using the
Quartus II Programmer to select a configuration bit stream file
with the .pof filename extension.
5. Once the programming operation is finished, set the
RUN/PROG slide switch back to the RUN position and then
reset the board by turning the power switch off and back on; this
action causes the new configuration data in the EPCS64 device
to be loaded into the FPGA chip.
73