temp-gard / temp-chart Measure what you see.
Please note the detailed operating instructions in English on CD. BYK-Gardner GmbH Lausitzer Strasse 8 82538 Geretsried Germany BYK-Gardner USA 9104 Guilford Road Columbia · MD 21046 USA Tel. +49-8171-3493-0 Fax +49-8171-3493-140 www.byk.com/instruments Phone +1-301-483-6500 Fax +1-301-483-6555 www.byk.
Measure what you see.
Measure what you see.
Measure what you see. How to transfer data to temp-chart? • Switch on the temp-gard logger • Connect USB-Stick to temp-gard logger • Data will be automatically saved on the USB-Stick • Select file to be transferred g Organizer name will be offered as file name (changeable) 1.
Measure what you see.
Measure what you see. How to Set Curing Conditions? How to set a QC-Procedure? The paint makers recommended temperature/time conditions will be compared to the actual temperature/time.
Measure what you see. How to create a Cure Chart? • Select Objects • Select Cure Chart • There are different possibilities to edit the area g Typing into the table duration time & temperature g Grabbing the box at the edges • Right mouse click to create a new cure chart g Empty Cure Chart template will appear ENGLISH g Name Cure Chart by pressing “Save As” button g Select a color e.g.
Measure what you see. How to set Pass / Fail Conditions? Database Handling • Select Objects • There are different ways to create or change the database • Select Pass Fail • Right mouse click to create Pass / Fail Conditions g Empty Pass / Fail template will appear ENGLISH g Name Pass / Fail by pressing “Save As” button g Select a Criterion Edit Functions • Menu Data g Edit tab g Comment, allows to put in comments after data transfer.
Measure what you see. How to display multiple measurements? Overlay g display of several measurements – no saving • Open the desired measurement from database pane curve will be displayed • Right mouse click into database pane to pick out the second curve select “Overlay” ENGLISH • Select “Merge” to combine several measurements g Analyze table lists sensors of all selected measurements g Analysis will be done according to the first selected measurement.
Measure what you see. temp-chart Hardware Requirements Accuracy +/- 0.5 °C PC with Pentium processor Resolution 0,10 °C from 0 – 400 °C 0.18 °F from 32 – 752 °F Interface USB port Memory min 256 MB RAM recommended 512 MB No. of Channels 6 or 12 Memory 20,000 readings per channel Hard Disk Capacity min 100 MB Sampling interval 0.1 sec up to 24 hrs Disk drive CD-ROM Temperature Range 0 – 400 °C (32 – 752 °F) Monitor resolution XGA (1024 x 768) or higher Battery Capacity 0.