Specifications

29
E-200 SERIES INTERCOM SYSTEM — EF-200 DUAL CHANNEL MASTER STATION
11. TECHNICAL SPECIFICATIONS 
IMPEDANCE: 
•   220 Ω AC. 
•  4700 Ω DC. 
NOMINAL/MAXIMUM LEVEL: 
•  -10 dBu / +3 dBu. 
INTERCOM LINE
FREQUENCY RESPONSE: 
•  100 Hz — 10 KHz (-3 dB). 
VOLTAGE OPERATION: 
•  +12 to +30 VDC. 
DYNAMIC RANGE: 
•  80 dB. 
BRINGING IMPEDANCE @ 1KHz: 
•  > 20 KΩ. 
SIDE-TONE CANCELLATION: 
•  Adjustable from 0 to 30 dB @ 1khz 
MICROPHONE LIMITER: 
•  Range: 28 dB. 
MAXIMUM CABLE LENGTH: 
•  500-2.000 mts. Depends on installation. 
RECOMMENDED WIRE TYPE: 
•  Shielded mic cable 2 x 0,30 mm
2
. 
CALL SIGNAL: 
•  +2,8 mA/11 VDC. 
CALL THRESHOLD: 
•  3 VDC. 
REMOTE MIC-OFF: 
•  Power interruption: 100 ms. 
SYSTEM 
SPECIFICATIONS
REMOTE BUZZER-OFF: 
•  10 Hz / 800 mVp. 
MICROPHONE TYPE: 
•  Dynamic or electret. 
INPUT IMPEDANCE: 
•  4K7. 
NOMINAL/MAXIMUM LEVEL: 
•  -45 dBu (H)/-20 dBu(L). 
LIMITER RANGE: 
•  28 dB. 
PRESENCE FILTER: 
•  +6 dB @ 4700 Hz. 
PREAMPLIFIER
PHANTOM VOLTAGE: 
•  +9 VDC (internal preset ). 
IMPEDANCE: 
•  200 Ω (nominal), 2KΩ (maximum). 
MAXIMUM LEVEL: 
•  20 Vpp (200 Ω). 
OUTPUT POWER: 
•  250 mW (200 Ω). 
FREQUENCY RESPONSE: 
•  250 Hz - 15 KHz. 
HEADSET AMPLIFIER
RESIDUAL NOISE: 
•  -100 dBu (all mics off). 
TYPE: 
•  Balanced, XLR-3-32. 
OUTPUT IMPEDANCE: 
•  100 Ω. 
P.A. OUTPUT
NOMINAL/MAXIMUM LEVEL: 
•  +4 dBu/+8 dBu. 
TYPE: 
•  Balanced, XLR-3-31. 
IMPEDANCE (LINE/MIC): 
•  40 KΩ / 2 KΩ. 
PROGRAM INPUT 
INPUT LEVEL: 
•  MIC: adjustable -15 dBu to -45 dBu. 
•  LINE: adjustable +10 dBu to -20 dBu. 
CONNECTIONS: 
•  1 NO+1 NC circuit /JACK ¼”. 
CONTACTS: 
•  0,5 Amp @ 125 VAC/ 1 Amp @ 30 VDC. 
PA RELAY 
RELAY ACTIVATION: 
•  By PA, mic-on A/B, buzzer mute keys. 
SYSTEM CABLING: 
•  Master-slave link with standard RJ-45 (8). 
MULTICHANNEL 
OPERATION 
CHANNELS: 
•  Maximum recommended: 10 (5 stations). 
MAINS VOLTAGE: 
•  90-264 VAC/ 50-60 Hz. 
POWER SUPPLY: 
•  24 VDC nominal/ 1,8 Amperes. 
PROTECTIONS: 
•  Short circuit on the line, overheat. 
POWER SUPPLY 
POWER REQUIREMENTS: 
•  50 VA maximum. 
BATTERY TYPE: 
•  Alkaline 9 V. (rear panel compartment). 
EMERGENCY SYSTEM OPERATION: 
•  12 VDC /500 mA max. 
EMERGENCY INTERVALS: 
•  10 minutes to auto switch-off. 
EMERGENCY SUPPLY 
ESTIMATE BATTERY LIFE: 
•  1 hour (4 beltpacks system). 
PROGRAM INPUT TRANSFORMER: 
•  REF: TDA-I. 
P.A. OUTPUT TRANSFORMER.: 
•  REF: TDA-O. 
PLASTIC SECURITY COVER: 
•  REF: TP-1. 
ACCESSORIES 
METAL, KEY PROTECTED SECURITY COVER: 
•  REF: TPS-1. 
DIMENSIONS 
•  1U x 19""x210 MM. 
WEIGHT 
•  3Kg. Net. 
NOTE: Technical specifications are subject to variation without previous notice. 