Instructions / Assembly
Assembling & Using Your Product
Unpack all components carefully. Please check to ensure all parts have been
removed from the packaging. Some splashing may occur.
Components:
• Fountain
• Pump
• LED Lights
• Back cover
• Transformer
Assembling:
• Place the fountain on a flat surface.
• Connect the vinyl tubing to the pump; adjust the flow control to the lowest
setting to avoid splashing until the fountain is completely assembled.
• Connect the light cables together to the pump.
• Slide the back cover in place.
• Connect the pump cord to the transformer.
• Gently pour water into the fountain, being careful not to overflow and
cause splashing. Make sure the water completely submerges the pump
and the water runs clear during operation. Plug the transformer into your
local power supply, make sure that there is no water around the plug &
always keep the power source in a dry place.
o NOTE: We recommend that you use distilled water to preven
t
scale build-up. The first time you operate the pump it can take
up to 5 minutes for the air to be completely expelled and wate
r
begins to flow properly.
Trouble Shooting & Caution
If you have any questions and/or problems, please contact the retail store you
purchased this fountain.
• If your pump fails to run
• Check the circuit breaker or try a different outlet to make sure the pump is
receiving electrical power.
• Check the pump discharge and tubing for any kinks and/or obstructions.
• Any buildup obstructing the water flow can be flushed with a garden hose.
• Check the rotor by removing the front cover & plate to access the impellor area.
Turn the rotor and make sure that the rotor is not jammed or broken.
• If your pump “spews”
•
Check the water level to make sure the pump is completely submerged and if
there is enough water in the basin to operate your fountain. Not having enough
water will cause your pump to spew.
• If your pump is making abnormal loud noises
•
Disconnect the pump from the electrical power supply and remove the front
cover & plate.
• Carefully grip the impellor and gently pull the impellor/rotor assembly out
of the pump housing.
• Rinse the impellor/rotor assembly and clean the cavity with clean water. If
breakage or damage is found, contact your local retailer for parts.
• Caution
o Always unplug the pump from the electrical outlet before
cleaning & handling.
o Use with clean water only. Do not place the fountain and/or
parts in any other liquid.
o Periodically change water & clean the pump to keep free
from micro-organisms.
o Disconnect and store the unit in a dry place if not in use for
an extended period of time.
o Do not operate with water above 90°F or 30°C.
o Do not lift, carry or pull the pump by the power cord.
o Do not exceed the maximum voltage & wattage on
transformer.
o NEVER LET THE PUMP RUN DRY.