Revolv Coil Installation Instructions
5
Figure “A” Drain Pan Gaskets
THE ACCESSORY PACKAGE TO BE USED WITH THE MANUFACTURED (MOBILE) HOME PLASTIC PAN CONTAINS
A
90 DEGREE ELL THAT CAN BE SCREWED IN THE LEFT DRAIN FITTING, THEN TURNED DOWN AND EXIT THE
FURNACE
HAND TIGHTEN ONLY – OVERTIGHTING CAN RESULT IN CRACKS IN THE DRAIN PAN
ENCLOSED DRAIN HOSE WILL SLIP OVER THE FITTING OR A STANDARD PVC FITTING CAN BE USED IF CODE
REQUIRES.
RIGHT DRAIN CONNECTION HAS A PLUG IN IT TO PREVENT FLOW UNLESS A SECONDARY DRAIN IS REQUIRED.
A STRAIGHT FITTING CAN BE USED FOR THE AUXILIARY DRAIN WHERE REQUIRED (FIELD SUPPLIED).
REMOVE PLUG AND INSERT FITTING, THEN TURN DOWN USING A STANDARD 3/4” PVC ELL.
INSTALLATION OF A COLLAPSIBLE HOSE ON SINGLE / AUXILIARY CONDENSATE DRAIN CONNECTION IS
RECOMMENDED.
CAUTION – BEFORE INSTALLING COIL IN FURNACE, SEE FIGURE 2.
SLIP 1” ID SECTION OF HOSE ONTO 90 DEGREE DRAIN FITTING.
HOSE IN SOME CASES IS VERY TIGHT BUT IT WILL STRETCH AS IT IS WORKED ON.
DRAIN HOSE CAN BE IN PLACE DURING INSTALLATION PROVIDING THE CLAMPS ARE SECURELY FASTENED.
IF THE DRAIN HOSE MUST BE REMOVED TO COMPLETE THE INSTALLATION, MAKE SURE THE HOSE IS
STRETCHED,
REATTACHED AND SECURELY FASTENED WITH THE CLAMPS BEFORE COMPLETING THE INSTALLATION
NOTE: Good preventive maintenance on heat pumps is critical to ensure proper airflow across the coils. Low airflow on indoor coils
during winter months causes high head pressures and premature compressor damage due to oil breakdown. This problem is normally
the result of a dirty air filter. The installer should instruct the homeowner of the importance of keeping filters clean.
CONTACT US FOR HELP OR FOR ANY COMMENTS ON OUR PRODUCTS.
As we strive to better serve our customers like you, we are always ready to help you. We also welcome any comments from our customers
concerning quality and improvements that could be made to our products.
Thank you for the purchase of our product.