Split Air Conditioner OWNER'S MANUAL ALPICAIR A I R C O N D I T I O N E R S MODELS: AM2O-51HPDC1 AM4O-81HPDC1 Thank you for choosing ALPICAIR air conditioners.Please read this manual 66129909219 attentively before starting up the unit and keep it carefully for future reference.
In line with the company’s policy of continual product improvement, the aesthetic and dimensional characteristics, technical data and accessories of this appliance may be changed without notice.
THE INSTRUCTIONS BEFORE USE GENERAL INFORMATION WARNING When having a burning smell or smoke, please turn off the power supply and contact with the service center . The power supply must adopt the special circuit that with air switch protection and assure it has enough capacity. The unit will be turned on or off according to your requirement Never cut off or damage power cables and control wires.
NAME OF PARTS GENERAL INFORMATION AM2O-51HPDC1: Warning Be sure to cut off the power supply before cleaning the air conditioner; otherwise electric shock might happen. Wetting of air conditioner may cause the risk of electric shock. Make sure not to wash your air conditioner in any case. Volatile liquids such as thinner or gasoline will cause damage to the appearance of air conditioner. (Only use soft dry cloth moist cloth clean the air conditioner cabinet).
GENERA L INFORM ATION TECHNICAL DATA MODE Electrical data Electricity supply Fuse or air switch Minimum power cord section AM2O-51HPDC1 220-240V~,50Hz 25 2.5 1400 mm2 L 818 mm P 378 mm H 596 mm Refrigerant gas(R410A) Size and clearance L P H GENERA L INFORM ATION TECHNICAL DATA MODE Electrical data Electricity supply Fuse or air switch Minimum power cord section AM4O-81HPDC1 220-240V~,50Hz 40 4.
ELECTRICAL CONNECTIONS INS TALLER AM2O-51HPDC1: 1. R emove the handle at the right side plate of the outdoor unit (one screw). AM2O-51HPDC1 2. Remove the cable clamp, connect the power connection cable with the terminal at the row of connection and fix the connection. The fitting line distributing must be Handle consistent with the indoor unit. terminal of line bank. Wiring should meet that of indoor unit. Front side plate 3. Fix power connection wire by wire clamp. 4.
ELECTRICAL CONNECTIONS INS TALLER AM4O-81HPDC1: 1. Remove the handle at the right side plate of the outdoor unit (one screw). An all-pole disconnection switch having a contact separation of at least 3mm in all pole should be 2. Remove the cable clamp, connect the power connection cable with the terminal at the row of connection and fix the connection. The fitting line distributing must be connected in fixed wiring. Wrong wire connection may cause malfunction of some electric components.
INSTALLING THE OUTDOOR UNIT Location Use bolts to secure the unit to a flat, solid floor. When mounting the unit on a wall or the roof, make sure the support is firmly secured so that it cannot move in the event of intense vibrations or a strong wind. Do not install the outdoor unit in pits or air vents Installing the pipes Use suitable connecting pipes and equipment for the refrigerant R410A.
MAINTENANCE INS TALLER Use suitable instruments for the refrigerant R410A. Do not use any other refrigerant than R410A. Do not use mineral oils to clean the unit. INSTALLATION DIMENSION DIAGRAM INS TALLER The installation must be done by trained and qualified service personnel with reliability according to this manual. Contact service center before installation to avoid the malfunction due to unprofessional installation.
CHECK AFTER INSTALLATION INSTALLER Check Items Problems Owing to Improper Installation Is the installation reliable? The unit may drop, vibrate or make noises Has the gas leakage been checked? May cause unsatisfactory cooling (heating) effect Is the thermal insulation of the unit sufficient? May cause condensation and water dropping Is the drainage smooth? May cause condensation and water dropping Does the power supply voltage accord with the rated voltage specified on the nameplate? The unit m