3.2.3 Time Parameters 
After making changes use the save changes button. 
1 – max. time, for which the DoorPhone is hanging up, this time can be 
extended during call by sign choice from telephone (* or #) – see page 22. 
2 – Number of incoming call rings, the DoorPhone pick up after preseted 
number of rings. After detection first ring – LED on front panel blinking. The 
number can be set from 1 to 9. 
3 – max. time [sec] among button presses [range 1-9] 
-  switch closing – if time between two next presses is bigger than w 
time, the code is not evaluated correctly. 
-  dialing – if the button, we are pressing, is the first password number 
for switch closing, so the choice is delayed by this w time. 
4 – time [sec] for which the guard will hang up, before repeated dialing (button 
pressing during call or dialing, busy tone detection) [range 1-5] 
5 – after finishing the dialing it calculates time (ringing tones). If the number 
exceeds time in second, it will hang up [range 10-99]. The dialing is 
repeated in case, when the dialing mode of 2 groups is set. 
6 – In default is status of DoorPhone signalling acoustically. If signalling makes 
problem, so this signalling pick up / hang up prohibited. 
7 – In default is status of DoorPhone signalling acoustically. If signalling makes 
problem, so this signalling others tones prohibited. 
8 – Default value – presetings to the firm settings. After making changes use 
the save changes button. 