User manual
25|Page
5. Switching between mode Day/Night can be either manual (using the codes above), or
automatic using the interval table (conditioned by the time server setting in the
“service”) file.
6. NOT USED in this version of the Door Entry System.
7. NOT USED in this version of the Door Entry System.
8. Default values – will perform basic factory reset.
After making changes don’t forget to click on “save changes.
Setting these parameters may fundamentally changes the functions of the System.
3.2.2 All about Relays
1. Relay modes:
=1 Switch mode –switches on by either command or password for a given time,
set in “relay closing” (used for electric locks, gate opening etc);
=2 Camera mode – switches the camera on when the System is activated and
off when the connection is terminated (hung up).
=3 Light mode – switches the LED light on when the System is activated (pick
up) for specified time (as set in “relay closing”).