Data Sheet
Product Specification Sheet APS998 - Rev. 09/2016
VSS110 Visual Staff Station (AlphaLinQ™ 100 series)VSS110 Visual Staff Station (AlphaLinQ™ 100 series)
42 Central Drive • Farmingdale • NY • 11735-1202 • Phone: (631) 777-5500 • Fax: (631) 777-559942 Central Drive • Farmingdale • NY • 11735-1202 • Phone: (631) 777-5500 • Fax: (631) 777-5599
TOLL-FREE: (800) 666-4800 • Web: AlphaCommunications.com • Email: info@alphacommunications.comTOLL-FREE: (800) 666-4800 • Web: AlphaCommunications.com • Email: info@alphacommunications.com
Copyright© 1998-2017 Alpha Communications® - All Rights Reserved.
Due to continuous product improvement, all colors, sizes, materials, finishes and specifications are subject to change without notice.
Architects' And Engineers' SpecificationsArchitects' And Engineers' Specifications
The visual Staff Station(s) shall be Alpha Communications®
AlphaLinQ™ 100 series model VSS110, or approved equal and shall
shall include an integral "CALL-PLACED" LED indicator, a "CALL"
button, and a "CANCEL" button. A call will be registered at the
annunciator panel, a corridor zone light (if installed), and the
station's CALL-PLACED" LED. All electronic components needed for
these features shall be mounted on a printed circuit board and all
station components shall be mounted an a rugged ABS plastic
faceplate. The station(s) shall be installed in a single gang ring
with square box. Plug-in connectors shall be provided for
connections. The VSS110 shall be UL® 1069 Listed to the latest
standards.
Contractor shall observe all local and national electrical and
building codes.
Required ComponentsRequired Components
AlphaLinQ™ 100 Annunciator unit and system components
AC152 Control Unit (req. SS106 Transformer)
VSS110 Visual Staff StationVSS110 Visual Staff Station
The Alpha Communications® VSS110 visual Staff Station
incorporates push button operation of call and cancel functions. A
call is registered at the annunciator panel and on a corridor light or
corridor zone light (if installed) when the call switch with integral
"CALL PLACED" LED is pushed. The "CALL PLACED" LED is also
illuminated. Calls are cancelled simply by depressing the "CANCEL"
button mounted on a rugged ABS plastic faceplate. The "CALL
PLACED" LED will also be extinguished.
The VSS110 is used primarily with the AlphaLinQ™ 100 series
visual nurse-call system, but can be used and is backwards
compatible with some older systems as well. The VSS110 is U.L.
1069 listed, to the latest standards.
FeaturesFeatures
U.L. 1069 Listed - to the latest standards
Simple Push-button Calling
Lighted CALL-PLACED LED Indicator and CALL button
Call-reset CANCEL Push-button
Flame Retardant type ABS White Plastic Faceplate
Corridor Zone Light Capability (optional)
SpecificationsSpecifications
Dimensions:
Height: 4.50" (114mm)
Width: 2.75" (69mm)
Depth: 1.75" (44mm)
Projects: 0.44" (11mm) from mounting surface
Mounting:
Steel City #52171 box with Steel City #52C14
plaster ring, or Alpha Communications® Model
#IH358 box with IH357 ring, or EXACT EQUAL.
Vertical mount.
Construction:
Flame retardant type ABS plastic
faceplate. Switches and electronic components
are circuit board mounted.
Connections: Plug-in connectors.
Optional ComponentsOptional Components
CDL101LED Corridor Dome Light w/1 White LED
CDL102LED Corridor Zone Light w/1 White and 1 Red LED
VPS101 Single Visual Patient Station
VPS102 Double Visual Patient Station
EPS155 Emergency Pull/Push Station (Toilet)
EPS156 Emergency Pull/Push Station (Code Blue)
EPS337 Emergency Pull/Push Station (Shower)
EPS339 Emergency Push Station (Mushroom Head)
VDS150 Duty Station