Specifications
36
745-838-B0-001
8.0 Specifi cations
General Specifications
General
Model: XP-EDH-A
Power Supplies Supported: XM2 (requires USM2 or USM2.5)
XM (requires USM)
Lectro ZTT, ZTT+
AM (requires APM card)
DOCSIS Compatibility: Firmware DOCSIS 1.1
Hardware DOCSIS 2.0
Monitoring Protocol: SNMPv1
RF Transmit/Receive
Tx Frequency Range: 5 to 42MHz
Output Power: 8 to 55dBmV
Channel Bandwidth: 6MHz
Receive Center Freq Range: 91 to 857MHz
(Standard, HRC, IRC channels)
Input Level: -15 to 15dBmV
Monitored Parameters
Power Supply Data
Number of Battery String: One to three of 36V or 48V
Battery Data: Individual Battery Voltages
Battery Compartment Temperature
Hardware
RF Cable Interface: F-connector, female, 75Ohm
LED Indicators: CMTS Registration
Upstream Activity
Downstream Activity
Unit Power
Environmental:
-40 to 65°C
10 to 90% non-condensing humidity
Emissio ns: EN50022 Class A and FCC Part 15 Class A
(Installed in power supply enclosure system)
Immunity: Surge Test per Specification (IEEE C62.41-1991)
ESD Protection:
±
8kV air discharge,
±
6kV contact
discharge as per (IEC 61000-4-2)
Warranty:
2 years
Dimensi ons (in): 5.2D x 8.6W x 1.3H
Management
NMS/EMS: • Standard SNMP Management Tools
HMS MIBs:
In addition to the standard DOCSIS MIBs, the transponder
supports the following HMS MIBs:
SCTE 25-3 (HMS-022): Interface
SCTE 36 (HMS-050): Root
MIB SCTE 37 (HMS-072): Tree
MIB SCTE 38-1 (HMS-026): Property
MIB SCTE 38-2 (HMS-023): Alarm MIB
SCTE 38-3 (HMS-024): Common
MIB SCTE 38-4 (HMS-027): Power Supply
MIB SCTE 38-6 (HMS-033): Generator
MIB SCTE 38-7 (HMS-050): TIB MIB
Ordering Information
Model Number Description
XP-EDH-A AlphaNet DSM Series External DOCSIS Transponder
CBL-PS-INT-01-003 Interface cable, XM, XM2 power supplies
CBL-PS-INT-01-002 Interface cable, AM/AP power supply
CBL-PS-INT-02-005 Interface cable, Lectro ZTT, ZTT+ power supplies
CBL-PS-PWR-01-001 Line voltage cable, XM, XM2, AM/AP, 120V
CBL-PS-PWR-03-002 Line voltage cable: XM, XM2, AM/AP, 220V
CBL-PS-PWR-02-002 Line voltage cable, Lectro 120VAC
CBL-PS-PWR-04-001 Line voltage cable, Lectro 220VAC
CBL-PS-BAT-04-004 Wire Kit, Battery Sense, 1x36V or 1x48V, 4’
CBL-PS-BAT-06-004 Wire Kit, Battery Sense, 2x36V, 4’
CBL-PS-BAT-08-004 Wire Kit, Battery Sense, 2x48V, 4’
CBL-PS-BAT-12-004 Wire Kit, Battery Sense, 3x48V, 4’
* Other Battery Sense Wire Kits available, call Alpha for more information
Model: XM2 XM AM ZTT Series
Major Alarm: X X X X
Minor Alarm: X X X X
Input Line Voltage: X X
1
X
1
X
1
Output Voltage: X X X X
1
Battery Voltage: X X X X
Output Current: X X X X
1
Standby/AC Line Fail: X X X X
Equipment/Test Fail: X X X
Enclosure Door Status: X X X X
Remote Test Control: X X X X
Notes:
1 Requires optional cable assembly