Specifications
29745-838-B0-001
4.0 Proprietary Management Information Bases (MIBs)
You need to use two proprietary MIBs from AM Networks to successfully confi gure the XP-EDH-A to
use the power supplies described in this manual. Compile these two MIBs onto a network manager or
MIB browser software.
Object Description
amDocsisDevicesTable
Oid: 1.3.6.1.4.1.2183.2.3.3.1.2
Set to the type of supply being monitored:
alphaXM2 (2) default
alphaXM (3)
alphaAM/AP (4)
lectroSentryII (5)
lectroZTT (6)
lectroZTTPlus (7)
amDocsisOPVoltageScaling
Oid: 1.3.6.1.4.1.2183.2.3.6.5
Set to 1 for DC powered transponders in Alpha XM2 type
supplies using USM2 or USM2.5 cards.
Set to 2 for DC powered transponders in Alpha XM type
supplies using USM cards.
Set to 3 for legacy power supplies (AM/AP, Lectro ZTT, ZTT+)
amDocsisInputVoltageMeasScaling
Oid: 1.3.6.1.4.1.2183.2.3.6.6
Set to 1 (default) for 110V powered supplies (Alpha or Lectro)
Set to 2 for 220V powered supplies (Alpha or Lectro)
Note: Presently this object is used in conjunction with Alpha’s
110V or 220V wall/brick transformers to sample the input line
voltage.
The scaled voltage available in the Alpha USM2.5 cards report
the input line voltage.
Table 4-1, Proprietary MIBs
To see a specifi c example of a MIBs fi le for a particular power supply, see that section of the manual.
The objects available are: