6. INSTALLATION
6.8.3 RPM (Remote Parallel Monitor)
The optional, RPM status monitoring logic upgrade plugs directly into connector J2 located
on the component side of the APM logic card (Rev 8 or higher). NOTE: Power must first be
removed before adding the RPM board (Refer to section 7.3 Power Module Shutdown).
Status monitoring interfaces are listed below and identified according to their manufacturer,
along with the associated parts. For additional installation information, refer to the RPM
operator's manual.
Configurations subject to change without notice.
RPM-T (Texscan Vital Signs "TDM-1A" and "RTDM-1A")
Designed for systems utilizing Texscan TDM-1A transponders. Transponders are internally mounted in Alpha power
supply enclosures.
Contact Alpha Technologies or your
nearest Alpha representative to order an
RPM kit according to your specific
enclosure. Please state enclosure type:
PWE, PME, UPE, UPE/M or other.
Tam
p
er Switch
Data
60 VAC Out
TDM-1A
US M - T
PO W E R SU PPL Y E NCL OS URE
SPI
12 0 V AC I n
Trunk In
Trunk Out
DC-16
RF+AC
RF In /O ut
Batteries
36 VDC
Al
p
ha Power
Module
RPM-AM (AM Communications "LANguard")
Designed for systems utilizing AM Communications TMC 8061 transponders. Transponders are internally mounted
in Alpha power supply enclosures.
Contact Alpha Technologies or your
nearest Alpha representative to order an
RPM kit according to your specific
enclosure. Please state enclosure type:
PWE, PME, UPE, UPE/M or other.
Alpha Power
Module
PO WE R S UP PL Y EN C LO S URE
120 V AC In
Tamp er S w itc h
Batter ies
36 VDC
TM C 80 6 1
RF I n/ O ut
Data
To CableTelevision
System
US M -A M
RPM-C (C-COR "Quick Alert")
Designed for systems utilizing C-COR “Quick Alert” transponders. The transponder is externally mounted in its own
enclosure.
Contact Alpha Technologies or your
nearest Alpha representative to order an
RPM kit according to your specific
enclosure. Please state enclosure type:
PWE, PME, UPE, UPE/M or other.
Order from C-COR:
5' data cable 172960-01
10' data cable 172960-02
20' data cable 172960-03
40' data cable 172960-04
RF In/O ut
60VAC Out
To C-COR"Quick Alert"
Transpo nde r
To CableT elevision
System
USM -C
PO WE R S UPPLY EN C LO S URE
120 V AC In
Tam
p
er Sw itc h
Batteries
36 VDC
Alpha Power
Module
RPM
RPM
RPM