Product Release 1 Setting Up the Amplifier
3c Align the connectors with both pins in their appropriate slots, then
gently but firmly push the connectors together so that they are fully
mated.
Figure 5-10
Connecting transformer to mains board
5.4 Connect the Cables
Procedure 5-4 Connect the cables
Step 1 Connect the power cord.
WARNING
!
WARNING! To avoid the hazard of a potentially fatal electric shock
and/or severe damage to the ALPHA 9500 and other equipment:
ALWAYS use an AC plug that is appropriate for the primary mains
voltage, current rating, and configuration.
ALWAYS use grounding type AC connectors that conform to local codes.
NEVER use 120-V-type plugs to connect to power receptacles for
190–250 V circuits.
ALWAYS connect ALL station equipment to a good common ground.
Failure to do so may allow RF feedback to leak into the transceiver and
cause severe signal distortion.