Specifications

Page 1/2
Test acc. to DIN 51302 part 2
Costumer :
Servi Motion
Order No.:
07/1285
Machine (Typ/Force/No./Year):
ALPHA 3-3000 , 3000kN , M.Nr.02643 , 2007
No. of Display/Trancducer:
C20/07020 , P8AP500bar/103410258
Calibration temperature:
20,0 (Raum) 20,5 °C (Calibration Loadcell)
Hardness of pressure plate:
57,5 HRC (top) 57,3 HRC (down)
Roughness of pressure plate:
0,55 µm (top) 0,59 µm (down)
Flatness of pressure plate:
O.K top O.K down
Druckkraftaufnehmer : Hottinger KD 2000 4x600 Werk-Nr. 89
Digitalkompensator : Hottinger DK 38 S6 S32 Werk-Nr. 20320005
Diameter of force transmitting area: 100 mm
Measuring range: 2000 kN
Tester: Nacke
Date of test: 19.03.2007
Remarks:
1. Test result: Self alignment of the upper pressure plate
%
M1
M2
M3
M4
allowed
10
0,00
0,02 -0,02 0,00 +/- 0,10
20
0,01
0,01 -0,02 0,01 +/- 0,10
40
0,01
0,00 -0,02 0,01 +/- 0,10
80
0,01
0,00 -0,02 0,02 +/- 0,10
100
0,01
-0,01 -0,02 0,02 +/- 0,10
2. Test result: Alignment of the component parts of the machine
%
M1
M2
M3
M4
allowed
10
0,05
0,05 0,03 0,03 0,10
20
0,02
0,02 0,03 0,03 0,10
40
0,01
0,01 0,02 0,02 0,10
80
0,01
0,01 0,01 0,01 0,10
100
0,01
0,01 0,01 0,01 0,10
3. Test result: Restraint on tilt of the upper pressure plate
%
Wv,h
Wl,r
allowed
10
0,041
-0,041 0,060
20
0,033
-0,033 0,050
40
0,027
-0,026 0,050
80
0,024
-0,023 0,040
100
0,023
-0,022 0,040
R
n
R
n