Specifications
• Sub-menu "Ramp, Cycles"
step on
The mode “adjustment” allows by means of deformation method a clamping of the tension specimen
or the manual extension of the piston to a bending specimen (option).
The selection of the control parameter makes force-, displacement-, deformation and external cont-
rolled tests possible. The piston is always extended in such a way that the specimen is touched by the
platen (frictional connection), except in case of “adjustment” mode (option for double display).
The cycle input permits repetitions. In case of abortion the last cycle number is indicated. If you input
cycle 0 it means that the machine is run to the max. force up to its standstill.
The holding time permits the holding of the maximal and minimal load.
The vel.-input is equivalent to the load increase per unit of time.
The machine is only charged to the minimal value when the number of cycles is higher or equal to 1.
If you select displacement, deformation or external as a control parameter, the load is replaced by the
respective parameter (option).
Page 13
3000 kN Test
M1
Cycles: 0
Hold: .00s
Vel:
Max:
Min:
01 kN/s
3000.000
kN
.000
kN
MA : Choice
ESC
: Abort