Instruction manual

Index to the AlphaBIOS Menu Functions
AlphaServer 1000/1000A Supplement 5-9
Fields in the hard disk configuration menu include:
Physical disk ID
. The physical disk ID is based on the SCSI ID. The disk with
the lowest SCSI ID is disk 0; the disk with the next lowest SCSI ID is disk 1, and
so on.
Controller
. The controller is the brand and model of SCSI chip used on the
SCSI controller.
Controller number
. The controller number is based on how many SCSI
controllers of a particular type are installed in the system. The first controller of a
type is always numbered 0. For example, if two NCR 810 controllers and one
QLogic controller existed in a system, they would be numbered as follows:
First NCR 810 = NCR810 #0, Second NCR 810 = NCR 810 #1, QLogic =
QLogic #0
SCSI ID number
. The SCSI ID number is a unique number you assign to each
SCSI device installed in the system. This is usually done via jumpers or a thumb
wheel attached to the drive housing or by jumpers supplied on the StorageWorks
backplane.
Size
. This is the raw capacity of the drive. Formatting the drive with different
file systems
for example, FAT and NTFS
may result in different usable sizes
because of the differences in how storage is managed under those file systems.
Drive manufacturer ID
. This line identifies the type of drive and the
manufacturer, as well as the firmware revision of the drive.
PCI Configuration Menu
Information about all the PCI devices in your system is presented when you select
“PCI Configuration” and press Enter. An example is shown in Figure 5-5.