Downgrading Your System
5–2 AlphaServer 1000/1000A CPU Upgrade Guide
UPD>
upd
Confirm update on:
SRM
ARC
[Y/(N)]
y
WARNING: updates may take several minutes to complete for each
device.
DO NOT ABORT!
ARC update for rev 4.nn is less than current rev 5.13
Continue [Y/(N)]
y
ARC Updating to 4.nn... Verifying 4.nn... PASSED.
SRM update for rev 4.nn is less than current rev 4.5-nn
Continue [Y/(N)]
y
SRM Updating to 4.nn ...Verifying 4.nn... PASSED.
UPD>
exit
Initializing...
When the
Initializing...
message displays, press the DC On/Off button to turn the
system off. Unplug the AC power cords for each power supply and remove the top cover
and left-side panel as described in your system Owner’s Guide.
Reset the J1 jumper on the CPU module to its standard boot setting (bank 0 for either
AlphaServer 1000; Bank 1 for AlphaServer 1000A systems).
Reinstall the top cover and side panel as described in the system Owner’s Guide and
reconnect the AC power cords for each power supply.
_________________________Caution____________________________
The SRM and ARC firmware you just re-installed are executable only on a
4/xxx CPU module.
____________________________________________________________
Power up the system.
Go to Chapter 4, the EISA Configuration Utility (ECU) must be run and some
environment variables need to be set.