CPU Module Installation and Firmware Update
AlphaServer 1000/1000A CPU Upgrade Guide 3–5
Verify Compares loadable and hardware images.
? or Help Scrolls this function table.
--------------------------------------------------------------
D. At the
UPD>
prompt, list the devices and revisions. For example:
UPD>
list
Device Current Revision Filename Update Revision
ARC 4.42-1 ARC_FW 5.13
SRM 4.2-74 SRM_FW 4.5-nnn
E. Update the firmware.
UPD>
upd
Confirm update on:
SRM
ARC
[Y/(N)]
y
WARNING: updates may take several minutes to complete for each
device.
DO NOT ABORT!
ARC Updating to 5.13... Verifying 5.13... PASSED.
SRM Updating to 4.5-nn ...Verifying 4.5-nn... PASSED.
UPD>
exit
Initializing...
F. When the
Initializing...
message displays, press the DC On/Off button to turn
the system off. Unplug the AC power cords for each power supply and remove the top
cover and left-side panel as described in your system Owner’s Guide.
G. Reset the J4 (or J1 depending on the CPU) jumper on the CPU module to its standard
boot setting (bank 0 for either AlphaServer 1000A or AlphaServer 1000 systems).
H. Reinstall the top cover and side panel as described in the system Owner’s Guide and
reconnect the AC power cords for each power supply.