User`s guide

ID Program Device Pass Hard/Soft Bytes Written Bytes Read
-------- ------------ ------------ ------ --------- ------------- -------------
00000001 idle system 0 0 0 0 0
0000002d exer_kid tta1 0 0 0 1 0
0000003d nettest era0.0.0.2.1 43 0 0 1376 1376
00000045 memtest memory 7 0 0 424673280 424673280
00000052 exer_kid dka100.1.0.6 0 0 0 0 2688512
00000053 exer_kid dka200.2.0.6 0 0 0 0 922624
>>> kill_diags
>>>
The system is tested and the system reports a fatal error message. No network
server responded to a loopback message. Ethernet connectivity on this system
should be checked.
>>> test
Requires diskette and loopback connectors on COM2 and parallel port
type kill_diags to halt testing
type show_status to display testing progress
type cat el to redisplay recent errors
Testing COM2 port
Setting up network test, this will take about 20 seconds
Testing the network
*** Error (era0), Mop loop message timed out from: 08-00-2b-3b-42-fd
*** List index: 7 received count: 0 expected count 2
>>>
3–6 Running System Diagnostics