Datasheet
Alpha Wire | www.alphawire.com | 1-800-52 ALPHA
Specifications subject to change. For complete specifications and availability, visit www.alphawire.com.
95
Xtra-Guard® Continuous Flex Data
C-Track or High Flexing Applications Up to 6 Million
Flex Life Cycles 300 V Foil/Spiral Shield, Multiconductor
UL CM
UL AWM 2661
CSA AWM I/II A/B FT4
CSA CMG
CE
Operating Temperature
• +5°C to 105°C (flexing)
• -10°C to 105°C (stationary)
Conductor Color Coding
• Chart D
• Jacket color: slate
Materials
• Finely stranded tinned
copper conductors
• Lubricated semi-rigid
PVC insulation
• Foil + spiral shield
Aluminum/polyester foil shield,
25% overlap min.
Foil facing outward
Tinned copper spiral shield,
90% coverage
• Oil-resistant PVC jacket
Availability
100 ft (30.5 m)
500 ft (152 m)
1000 ft (305 m)
Bulk, cut to length
FIT® Tubing Recommendations
• FIT-FLEX: Highly flexible,
cross-linked silicone rubber
• FIT-650: Chemical/
temperature resistant
cross-linked fluoroelastomer
28 AWG (0.09 mm
2
)
Stranding: 7/36 (7 x 0.13 mm)
Insulation thickness: 0.010 (0.25 mm)
Part No. Conductors
Nominal Diameter Jacket Thickness
Inch mm Inch mm
86002CY 2 0.174 4.42 0.040 1.02
86003CY 3 0.180 4.57 0.040 1.02
86004CY 4 0.190 4.83 0.040 1.02
86005CY 5 0.200 5.08 0.040 1.02
86007CY 7 0.223 5.66 0.040 1.02
86012CY 12 0.283 7.19 0.040 1.02
86018CY 18 0.282 7.16 0.040 1.02
86025CY 25 0.329 8.36 0.040 1.02
26 AWG (0.14 mm
2
)
Stranding: 7/34 (7 x 0.16 mm)
Insulation thickness: 0.010 (0.25 mm)
Part No. Conductors
Nominal Diameter Jacket Thickness
Inch mm Inch mm
86102CY 2 0.182 4.62 0.040 1.02
86103CY 3 0.188 4.78 0.040 1.02
86104CY 4 0.199 5.05 0.040 1.02
86105CY 5 0.211 5.36 0.040 1.02
86107CY 7 0.237 6.02 0.040 1.02
86112CY 12 0.303 7.70 0.040 1.02
86118CY 18 0.302 7.67 0.040 1.02
86125CY 25 0.355 9.02 0.040 1.02
24 AWG (0.20 mm
2
)
Stranding: 10/34 (10 x 0.16 mm)
Insulation thickness: 0.010 (0.25 mm)
Part No. Conductors
Nominal Diameter Jacket Thickness
Inch mm Inch mm
86202CY 2 0.192 4.88 0.040 1.02
86203CY 3 0.199 5.05 0.040 1.02
86204CY 4 0.211 5.36 0.040 1.02
86205CY 5 0.225 5.72 0.040 1.02
86207CY 7 0.253 6.43 0.040 1.02
86212CY 12 0.327 8.31 0.040 1.02
86218CY 18 0.327 8.31 0.040 1.02
86225CY 25 0.396 10.06 0.045 1.14
22 AWG (0.38 mm2)
Stranding: 19/34 (19 x 0.16 mm)
Insulation thickness: 0.010 (0.25 mm)
Part No. Conductors
Nominal Diameter Jacket Thickness
Inch mm Inch mm
86302CY 2 0.208 5.28 0.040 1.02
86303CY 3 0.217 5.51 0.040 1.02
86304CY 4 0.231 5.87 0.040 1.02
86305CY 5 0.247 6.27 0.040 1.02
86307CY 7 0.280 7.1 1 0.040 1.02
86312CY 12 0.367 9.32 0.040 1.02
86318CY 18 0.367 9.32 0.040 1.02
86325CY 25 0.446 11.33 0.045 1.14