Datasheet

Alpha Wire | www.alphawire.com | 1-800-52 ALPHA
Specifications subject to change. For complete specifications and availability, visit www.alphawire.com.
48
Xtra-Guard® 3
Direct Burial
300 V Foil Shield, Multiconductor
Operating Temperature
–30°C to +80°C
Conductor Color Coding
Chart D
Jacket Colors: Nine available
(black standard)
Materials
Stranded tinned copper
conductors
Premium PVC insulation
Specially formulated
polyethylene jacket
UV resistant
Aluminum/polyester foil shield,
with 25% overlap and foil
facing inward
Tinned copper drain wire sized
the same as cable conductors
Nylon ripcord
Availability
Made to order
1000 ft (305 m) minimum
FIT® Tubing Recommendations
FIT-700: Bonding,
thermoplastic adhesive lined,
cross-linked polyolefin
18 AWG (0.81 mm
2
)
Stranding: 16/30 (16 x 0.25 mm)
Insulation thickness: 0.016 (0.41 mm)
Part No. Conductors
Nominal Diameter Jacket Thickness
Inch mm Inch mm
35382 2 0.229 5.82 0.032 0.81
35383 3 0.241 6.12 0.032 0.81
35384 4 0.262 6.65 0.032 0.81
35386 6 0.309 7.85 0.032 0.81
35388 8 0.334 8.48 0.032 0.81
35390 10 0.387 9.83 0.032 0.81
35390/15 15 0.434 11.02 0.032 0.81
35390/20 20 0.485 12.32 0.032 0.81
35390/25 25 0.587 14.91 0.053 1.35
16 AWG (1.23 mm
2
)
Stranding: 19/0.0117 (19 x 0.29 mm)
Insulation thickness: 0.016 (0.41 mm)
Part No. Conductors
Nominal Diameter Jacket Thickness
Inch mm Inch mm
35362 2 0.253 6.43 0.032 0.81
35363 3 0.267 6.78 0.032 0.81
35364 4 0.291 7.39 0.032 0.81
35366 6 0.345 8.76 0.032 0.81
35368 8 0.374 9.50 0.032 0.81
35370 10 0.435 11.05 0.032 0.81
35370/15 15 0.489 12.42 0.032 0.81
35370/20 20 0.589 14.96 0.053 1.35
35370/25 25 0.659 16.74 0.053 1.35