Datasheet
Alpha Wire | www.alphawire.com | 1-800-52 ALPHA
Specifications subject to change. For complete specifications and availability, visit www.alphawire.com.
30
EcoFlex®
600 V Braid Shield, Multiconductor
UL AWM 21819 (600 V, 105°C)
UL AWM 21492 (300 V, 80°C)
UL VW-1
CSA I/II A/B FT1
Temperature Range
-40°C to + 80°C
Conductor Color Coding
• Chart D
Materials
• Tinned copper conductors
• mPPE insulation
• Tinned copper braid,
70% min. coverage
• mPPE jacket, slate
Bend Radius
• Unshielded: 5x static, 5x flexing
• Shielded: 6x static, 8x flexing
Properties
• Zero halogen
• Specific gravity: 1.03
• 100% recyclable
• Low outgassing
• Suitable for use in NFPA 79
applications
• IEC 60332-2 flame behavior
Availability
100 ft (30.5 m)
1000 ft (305 m)
Bulk
FIT® Tubing Recommendations
• FIT-221L: Low smoke
zero halogen
• FIT Spiral Wrap: Simplifies
wire harnessing, cabling,
and bundling
20 AWG (0.51 mm
2
)
Stranding: 10/30 (10 x 0.25 mm)
Insulation thickness: 0.010 (0.25 mm)
Jacket thickness: 0.035 (0.89 mm)
Part Number Conductors
Nominal Diameter
Inch mm
79101 2 0.210 5.33
79102 3 0.219 5.56
79103 4 0.233 5.92
79104 5 0.250 6.35
79105 7 0.266 6.76
79106 9 0.321 8.15
79107 12 0.329 8.36
79108 18 0.376 9.55
18 AWG (0.81 mm
2
)
Stranding: 16/30 (16 x 0.25 mm)
Insulation thickness: 0.010 (0.25 mm)
Jacket thickness: 0.035 (0.89 mm)
Part Number Conductors
Nominal Diameter
Inch mm
79109 2 0.236 5.99
79110 3 0.247 6.27
79111 4 0.264 6.71
79112 5 0.284 7.21
79113 7 0.305 7.75
79114 9 0.372 9.45
79115 12 0.381 9.68
16 AWG (1.32 mm
2
)
Stranding: 26/30 (26 x 0.25 mm)
Insulation thickness: 0.011 (0.28 mm)
Jacket thickness: 0.035 (0.89 mm)
Part Number Conductors
Nominal Diameter
Inch mm
79116 2 0.262 6.65
79117 3 0.275 6.98
79118 4 0.296 7.52
79119 5 0.320 8.13
79120 7 0.345 8.76
rBraid Shiled: Betteraid
: