Datasheet

Alpha Wire | www.alphawire.com | 1-800-52 ALPHA
Specifications subject to change. For complete specifications and availability, visit www.alphawire.com.
31
14 AWG (2.08 mm
2
)
Stranding: 41/30 (41 x 0.25 mm)
Insulation thickness: 0.011 (0.28 mm)
Jacket thickness: 0.035 (0.81 mm)
Part Number Conductors
Nominal Diameter
Inch mm
79121 2 0.294 7.47
79122 3 0.309 7.85
79123 4 0.335 8.51
79124 5 0.363 9.22
79125 7 0.392 9.96
12 AWG (3.29 mm
2
)
Stranding: 65/30 (65 x 0.25 mm)
Insulation thickness: 0.012 (0.30 mm)
Jacket thickness: 0.035 (0.81 mm)
Part Number Conductors
Nominal Diameter
Inch mm
79126 3 0.354 8.99
79127 4 0.386 9.80
UL AWM 21819 (600 V, 105°C)
UL AWM 21492 (300 V, 80°C)
UL VW-1
CSA I/II A/B FT1
Temperature Range
-40°C to + 80°C
Conductor Color Coding
• Chart D
Materials
• Tinned copper conductors
• mPPE insulation
Tinned copper braid,
70% min. coverage
• mPPE jacket, slate
Bend Radius
• Unshielded: 5x static, 5x flexing
• Shielded: 6x static, 8x flexing
Properties
• Zero halogen
• Specific gravity: 1.03
• 100% recyclable
• Low outgassing
Suitable for use in NFPA 79
applications
• IEC 60332-2 flame behavior
Availability
100 ft (30.5 m)
1000 ft (305 m)
Bulk
FIT® Tubing Recommendations
FIT-221L: Low smoke
zero halogen
FIT Spiral Wrap: Simplifies
wire harnessing, cabling,
and bundling
EcoFle
600 V Braid Shield, Multiconductor
rBraid Shiled: Betteraid
: