Datasheet
Alpha Wire | www.alphawire.com | 1-800-52 ALPHA
Specifications subject to change. For complete specifications and availability, visit www.alphawire.com.
34
12 AWG (3.29 mm
2
)
Stranding: 65/30 (65 x 0.25 mm)
Insulation thickness: 0.012 (0.30 mm)
Jacket thickness: 0.035 (0.81 mm)
Part Number Conductors
Nominal Diameter
Inch mm
79232 3 0.360 9.14
79233 4 0.391 9.93
79234 5 0.426 10.82
79235 7 0.462 11.73
10 AWG (5.32 mm
2
)
Stranding: 105/30 (105 x 0.25 mm)
Insulation thickness: 0.012 (0.30 mm)
Jacket thickness: 0.035 (0.81 mm)
Part Number Conductors
Nominal Diameter
Inch mm
79236 3 0.419 10.64
79237 4 0.457 11.61
14 AWG (2.08 mm
2
)
Stranding: 41/30 (41 x 0.25 mm)
Insulation thickness: 0.011 (0.28 mm)
Jacket thickness: 0.035 (0.81 mm)
Part Number Conductors
Nominal Diameter
Inch mm
79225 2 0.300 7.62
79226 3 0.315 8.00
79227 4 0.341 8.66
79228 5 0.369 9.37
79229 7 0.398 10.11
79230 9 0.493 12.52
79231 12 0.507 12.88
EcoFlex®
600 V Supra-Shield® Foil + Braid Shield, Multiconductor
UL AWM 21819 (600 V, 105°C)
UL AWM 21492 (300 V, 80°C)
UL VW-1
CSA I/II A/B FT1
Temperature Range
-40°C to + 80°C
Conductor Color Coding
• Chart D
Materials
• Tinned copper conductors
• mPPE insulation
• Supra-Shield foil + braid shield:
Aluminum/polyester/aluminum
foil with 25% overlap min.
Tinned copper drain wire
Tinned copper braid,
70% coverage min.
• mPPE jacket, slate
Bend Radius
• Unshielded: 5x static, 5x flexing
• Shielded: 6x static, 8x flexing
Properties
• Zero halogen
• Specific gravity: 1.03
• 100% recyclable
• Low outgassing
• Suitable for use in NFPA 79
applications
• IEC 60332-2 flame behavior
Availability
100 ft (30.5 m)
1000 ft (305 m)
Bulk
FIT® Tubing Recommendations
• FIT-221L: Low smoke zero halogen
• FIT Spiral Wrap: Simplifies
wire harnessing, cabling,
and bundling