Hook-Up Wire
Everything You Need to Hook Up Anything T he broad range of hook-up wire from Alpha Wire means you will find the wire exactly suited to your application— whether it’s as straightforward as a control cabinet in a protected environment or as specialized as a machine tool on the factory floor, a hightemperature oven, or off-road construction equipment.
Choice of Features and Approvals by Application Voltage Insulation Wire Range (AWG) Approvals CSA Temperature Range CSA AWM I A/B FT1 -55°C to +105°C Stranded Solid UL XL-PVC 26 – 16 — XLPE 22 – 18 — UL AWM 3265 UL AWM 1569 -40°C to +105°C PVC 30 – 16 24 – 16 UL AWM 1007 -40°C to +80°C Page No.
600 V, mPPE Wire EcoWire® Innovative EcoWire combines increased performance with a minimized environmental impact. Compared to PVC wire, EcoWire’s modified polyphenylene ether (mPPE) insulation allows wire that are: Part No. 6710 6711 6712 6713 6714 6715 6715S 6716 6717 6717S 6718 6719 Conductor Size AWG mm2 28 0.08 26 0.13 24 0.20 22 0.32 20 0.52 18 0.82 18 0.82 16 1.30 14 2.08 14 2.08 12 3.30 10 5.26 Stranding AWG mm 7/36 7 x 0.12 7/34 7 x 0.16 7/32 7 x 0.20 7/30 7 x 0.25 10/30 10 x 0.25 16/30 16 x 0.
300 V, PVC Wire UL AWM 1007, 1581, 1569 VW-1 CSA AWM I A/B FT1 CSA TR-64 FT1 - 40°C to +105°C (AWM 1569, CSA AWM) -40°C to +90°C (CSA TR-64) -40°C to +80°C (AWM 1007, 1581) Stranded or solid tinned copper conductor PVC insulation Availability 100 ft (30.5 m) 1000 ft (305 m) Part No.
00 V, PVC Wire UL AWM 1015, 1028, 1230, 1231, 1232, 1283, 1284 UL MTW (22 to 1/0 AWG) UL THW (6 to 1/0 AWG) CSA AWM I A/B FT1 and TEW 105 UL VW-1 - 20°C to +105°C (AWM, TEW) -20°C to +90°C (MTW) -20°C to +75°C (THW) -20°C to +60°C (TW) Stranded or solid tinned copper conductor Availability 100 ft (30.5 m) 1000 ft (305 m) Part No.
600 V, PVC Wire MIL-DTL-16878/1 (Type B) MIL-W-76 Type LW -55°C to +105°C Stranded or solid tinned copper conductor PVC insulation Availability 100 ft (30.5 m) 1000 ft (305 m) Part No. 1850 1851* 1852* 1853* 172619 1854* 1854/19 1855 1855/19 1856* 1856/19 1857 1857/19 1858/19 1859/19 Wire Size AWG 32 30 28 26 26 24 24 22 22 20 20 18 18 16 14 Stranding mm2 0.03 0.06 0.09 0.14 0.15 0.23 0.24 0.35 0.38 0.56 0.62 0.90 0.96 1.23 1.
1000 V, PVC Wire MIL-W-76 Type MWP -55°C to +90°C Stranded or solid tinned copper conductor PVC insulation Availability 1000 ft (305 m) Part No. 302407 302207 302010 301816 301626 301619 301441 Wire Size AWG 24 22 20 18 16 16 14 mm2 0.23 0.35 0.51 0.81 1.32 1.23 2.08 Stranding AWG 7/32 7/30 10/30 16/30 26/30 19/29 41/30 mm 7 x 0.20 7 x 0.25 10 x 0.25 16 x 0.25 26 x 0.25 19 x 0.29 41 x 0.25 Insulation Thickness Inch mm 0.016 0.41 0.016 0.41 0.016 0.41 0.016 0.41 0.016 0.41 0.016 0.41 0.016 0.
1000/300 V, Irradiated PVC Wire Soldering Iron Resistant MIL-DTL-16878/2 (Type C) (1000 V) UL AWM 1430 (300 V) CSA REW XLPVC FT1 (300 V) -55°C to +105°C Stranded tinned copper conductor Irradiated PVC insulation Availability 100 ft (30.5 m) 1000 ft (305 m) Part No. 7130 7131 7132 7133 7134 7035* 7036* Wire Size AWG 24 22 20 18 16 14 12 mm2 0.23 0.35 0.56 0.89 1.32 2.07 3.29 Stranding AWG 7/32 7/30 7/28 7/26 19/0.0117 19/0.0147 19/0.0185 mm 7 x 0.20 7 x 0.25 7 x 0.32 7 x 0.40 19 x 0.30 19 x 0.
00/300 V, XLPE MIL-DTL-16878/2 (Type C) (1000 V) UL AWM 3266 (300 V) VW-1 CSA CL 1252 XLPE (300 V) - 55°C to +105°C (MIL) -55°C to +125°C (UL, CSA) Stranded tinned copper conductor Part No. 7024 7025 7026 Wire Size AWG 22 20 18 mm2 0.38 0.62 0.96 Stranding AWG 19/34 19/32 19/30 mm 19 x 0.16 19 x 0.20 19 x 0.25 Insulation Thickness Inch mm 0.016 0.41 0.016 0.41 0.016 0.41 Nominal Diameter Inch mm 0.064 1.63 0.072 1.83 0.080 2.
250 V, PTFE Wire MIL-DTL-16878/6 (Type ET) UL VW-1 NEMA HP3 -60°C to +200°C tranded or solid silverS plated copper conductor PTFE insulation Availability 100 ft (30.5 m) 1000 ft (305 m)* *May contain multiple lengths Part No. 33201 2840/7* 2841/7* 2841/1* 2842/7* 2842/19* 2842/1* 2843/7* 2843/19* 2843/1* 2844/7* 2844/19* 2845/7 2845/19 Wire Size AWG 32 32 30 30 28 28 28 26 26 26 24 24 22 22 mm2 0.03 0.03 0.06 0.05 0.09 0.09 0.08 0.14 0.15 0.13 0.23 0.24 0.35 0.
1000/300 V, PTFE Wire MIL-DTL-16878/5 (TYPE EE) (1000V) UL AWM 1180 (300V) NEMA HP3 -60°C to +200°C Stranded or solid silver-plated copper conductor PTFE insulation Availability 100 ft (30.5 m) 1000 ft (305 m)* *May contain multiple lengths Part No. 5874 5875 5876 5877 5878 5879 5879/10 5879/12 5879/8* Wire Size AWG 24 22 20 18 16 14 10 12 8 mm2 0.24 0.38 0.62 0.96 1.23 1.94 4.74 3.08 8.61 Stranding AWG 19/36 19/34 19/32 19/30 19/29 19/27 37/26 19/25 133/29 mm 19 x 0.13 19 x 0.16 19 x 0.20 19 x 0.
Wire Wrap, PVDF or ETFE Wire UL 1422, 1423, 1516, 1523 VW-1 -40°C to +125°C (PVDF) -70°C to +150°C (ETFE) +105°C (UL) Silver-plated solid copper conductors PVDF or ETFE insulation Availability 100 ft (30.5 m) (ETFE) 1000 ft (305 m) (PVDF or ETFE) PVDF Insulation Part No. 5951 5952 5953 5954 Wire Size AWG mm2 30 0.05 28 0.08 26 0.13 24 0.20 Insulation Thickness Inch mm 0.005 0.11 0.006 0.14 0.006 0.14 0.005 0.11 Nominal Diameter Inch mm 0.019 0.51 0.024 0.61 0.027 0.69 0.030 0.
High Voltage, Silicone Rubber Wire UL AWM 3239 -40°C to +150°C Stranded tinned copper conductor Silicone rubber insulation Availability 100 ft (30.5 m) 500 ft (152 m) 1000 ft (305 m) UL 3239 Part No. 392297 392275 392262 392250 392245 392240 392097 392075 392062 392050 392045 392040 391897 391875 391862 391850 391845 391840 391699 391697 391675 391662 391650 391645 391640 391499 391497 391475 391462 391450 391445 391440 Wire Size AWG mm2 22 0.35 22 0.35 22 0.35 22 0.35 22 0.35 22 0.35 20 0.51 20 0.
High Voltage, Silicone Rubber Wire UL VW-1 -40°C to +200°C tranded silver-plated S copper conductor White silicone rubber insulation Availability 100 ft (30.5 m) 500 ft (152 m) 1000 ft (305 m) Wire Size Part No. 39X2220 39X2215 39X2205 39X2025 39X2020 39X2015 39X1825 39X1660 39X1645 39X1635 39X1620 39X1460 39X1260 AWG 22 22 22 20 20 20 18 16 16 16 16 14 12 mm2 0.35 0.35 0.35 0.62 0.62 0.62 0.96 1.32 1.23 1.23 1.33 1.94 3.
600 V, PTFE/Glass Braid Wire High-Temperature UL AWM 5196 CSA AWM I A/B -55°C to +250°C tranded nickel-plated S copper conductor White PTFE tape insulation Double fiberglass serve Tan PTFE-impregnated fiberglass jacket Part No. 3131816 3131626 3131441 3131265 3131000 3138133 3136133 Wire Size AWG 18 16 14 12 10 8 6 Insulation Thickness Inch mm 0.016 0.41 0.016 0.41 0.016 0.41 0.016 0.41 0.016 0.41 0.016 0.41 0.016 0.41 Stranding AWG 19/30 26/30 41/30 65/30 105/30 133/29 133/27 mm2 0.81 1.32 2.08 3.
150/600 V, PVC Ribbon Cable MIL-DTL-16878/1 (Type B) (600 V) UL AWM 2713 (150 V) VW-1 -20°C to +105°C (MIL) -20°C to +80°C (AWM) Brown, red, orange, yellow, green, blue, violet, slate, white, black . . . repeats Stranded tinned copper conductors Color-coded PVC insulation bonded into a flat configuration 26 AWG (0.14 mm2) Stranding: 7/34 (7 x 0.16 mm) Insulation thickness: 0.010 (0.25 mm) Cable height: 0.039 (0.99 mm) Part No. Conductors 3550 3550/14 3551 3551/16 3553 10 14 15 16 30 Width Inch 0.
300/1000 V, PVC Ribbon Cable MIL-DTL-16878/2 (Type C) (1000 V) UL AWM 2555 (300 V) -20°C to +105°C (MIL) -20°C to +80°C (AWM) Brown, red, orange, yellow, green, blue, violet, slate, white, black . . . repeats Stranded tinned copper conductors 22 AWG (0.35 mm2) Stranding: 7/30 (7 x 0.25 mm) Insulation thickness: 0.016 (0.41 mm) Cable height: 0.065 (1.65 mm) Part No. Conductors 3505 3510 3515 3520 5 10 15 20 Width Inch 0.310 0.620 0.930 1.240 mm 7.87 15.75 23.62 31.
Hook-Up Wire Kits Part No. Alpha’s hook-up wire kits contain an assortment of 100 ft (30.5 m) spools of hook-up wire suitable for military or UL/CSA applications. These kits have been designed for use by technicians, engineers, and designers in the R&D lab or maintenance shop. Each kit contains a stripping tool and five spools of hook-up wire in a unique, rack-mounted, transparent dispensing tube. The tube and rack system keeps hook-up wire neat, clean, and conveniently at hand.
The cables you trust. The service you deserve. Every application is critical and wire failure is not an option when the safety of your equipment and personnel is paramount. Specify Alpha hook-up wire for harsh environments and crucial applications; since the integrity of your system is only as robust as the products you use. GLOBAL HEADQUARTERS 711 Lidgerwood Avenue Elizabeth, NJ 07207-0711 USA Toll Free: 1-800-52 ALPHA Tel: 1-908-925-8000 Fax: 1-908-925-5411 E-mail: info@alphawire.